A hybrid denture is one that is fabricated over a metal framework and retained by screws threaded into the implant abutments. The anterior part of a mandibular hybrid denture is fixed on implants while the posterior part of the denture is extended and cantilevered from implants. This article presents the fabrication of a maxillary over-denture opposing mandibular implant retained hybrid prosthesis. A total of four implants were placed in the mandibular arch. Castable abutments were used to produce the optimal angulations. Framework was waxed, cast recovered, and the fit was refined until the framework seated passively on the master cast. The mandibular denture teeth were waxed to the hybrid framework, and a final wax try-in was performed to verify and correct maxillomandibular relations before processing. The prosthesis was inserted after verification of occlusion, retention, and stability. The rehabilitation of edentulous patients with hybrid dentures has been observed to achieve greater masticatory function and psychological satisfaction than with conventional over-dentures. Producing a passive-fitting substructure for a fixed removable screw retained hybrid prosthesis is arguably one of the most technically complex tasks in implant dentistry. The technique presented may not initially produce a perfectly passive framework, but use of disclosing media and adjusting the internal aspect of the casting can result in non-binding, fully seated prostheses.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3757889 | PMC |
http://dx.doi.org/10.4103/0976-237X.114862 | DOI Listing |
Sci Rep
January 2025
Department of Oral and Maxillofacial Surgery, University Medical Center Groningen, University of Groningen, Hanzeplein 1, P.O. Box 30.001, 9700 RB, Groningen, The Netherlands.
In cases of large mandibular continuity defects resulting from malignancy resection, the current standard of care involves using patient-specific/custom titanium reconstruction plates along with autogenous grafts (fibula, scapula, or iliac crest segments). However, when grafts are not feasible or desired, only the reconstruction plate is used to bridge the gap. Unfortunately, metal osteosynthesis and reconstruction plates, including titanium, exhibit adverse effects such as stress-shielding and limitations in accurate postoperative irradiation (especially with proton-beam therapy).
View Article and Find Full Text PDFJ Indian Prosthodont Soc
January 2025
Department of Prosthodontics, K M Shah Dental College and Hospital, Sumandeep Vidyapeeth, Vadodara, Gujarat, India.
Aim: The aim is to evaluate and compare stress distribution characteristics of ball, magnet, and positioned attachment systems in single and double implant-retained overdentures using the finite element method (FEM).
Setting And Design: In vitro (in silico study) finite element analysis (FEA).
Materials And Methods: A Styrofoam mandible with duplicated silicon mucosa was used to construct a mandibular complete denture.
BMC Oral Health
January 2025
Department of Oral Implantology, School and Hospital of Stomatology, Guangdong Engineering Research Center of Oral Restoration and Reconstruction & Guangzhou Key Laboratory of Basic and Applied Research of Oral Regenerative Medicine, Guangzhou Medical University, Guangzhou, 510182, China.
Background: Fibrous dysplasia (FD) is a self-limiting benign disease with slow progression in which the normal bone is replaced by dysplastic fibrous tissue. The craniofacial skeleton is one of the most commonly affected areas, and it can create unique challenges in dental implant therapy. This case aims to report an unusual presentation of FD localized in the alveolar crest bone of the edentulous site, causing special obstacles to implant placement, and provide a diagnostic and treatment process that may be referenced.
View Article and Find Full Text PDFImaging Sci Dent
December 2024
Department of Neurosciences, Reproductive and Odontostomatological Sciences, University of Naples Federico II, Naples, Italy.
Purpose: This study aimed to evaluate the impact of a metal artifact reduction (MAR) algorithm on cone-beam computed tomography (CBCT) scans of titanium and zirconia implants, both within and outside the field of view (FOV).
Materials And Methods: In this study, a dry human mandible was positioned in a CBCT scanner with only its left quadrant included in the FOV. Each type of implant (titanium and zirconia) was placed once in the right second premolar extraction socket and once in the left second premolar extraction socket of the mandible.
J Korean Assoc Oral Maxillofac Surg
December 2024
Department of Oral and Maxillofacial Surgery, Hallym University Sacred Heart Hospital, Anyang, Korea.
The submandibular displacement of a mandibular third molar residual root presents major challenges to oral and maxillofacial surgeons due to the proximity to critical anatomical structures such as the lingual nerve and sublingual artery. Preoperative imaging can approximate the location of the residual tooth root; however, accurately determining its exact position is difficult because of the dynamic nature of the mandible and the difficulty of real-time synchronization of imaging. This study presents the successful extraction of a residual mandibular third molar root in a 67-year-old female patient achieved using a magnetic field-based navigation system.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!