Ultrasonic transcutaneous energy transfer is an effective method for powering implanted devices noninvasively. Nevertheless, the amount of power harvested by the implanted receiver is sensitive to the distance and orientation of the external transmitting transducer attached to the skin with respect to the implanted receiving transducer. This paper describes an ultrasonic power transfer link whose harvested power is controlled by an inductive link. A small (5 μF) storage capacitor voltage, which is part of the implanted unit, is allowed to swing between 3.8 and 3.5 V using hysteretic control. The two control states are indicated by excitation (while the implanted storage capacitor voltage decreases) or the absence of excitation of an implanted coil that is magnetically coupled to an external coil attached to the skin surface. A 35 mW Ultrasonic Transcutaneous Energy Transfer link was fabricated using two piezoelectric transducers of equal size (Fuji Ceramics C-2 PZT disc 15 mm × 3 mm) operated at a vibration frequency of 720 kHz. By applying the proposed hysteretic control, the captured power was effectively regulated for implantation depths of up to 85 mm.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TBME.2013.2280460DOI Listing

Publication Analysis

Top Keywords

ultrasonic transcutaneous
12
transcutaneous energy
12
energy transfer
12
transfer link
12
attached skin
8
storage capacitor
8
capacitor voltage
8
hysteretic control
8
excitation implanted
8
implanted
7

Similar Publications

Background: Preclinical studies have demonstrated that therapeutic ultrasound (TUS) increases perfusion in peripheral artery disease (PAD). This pilot study assessed the safety and effectiveness of a noninvasive TUS device in patients with advanced PAD.

Methods: A phased array of TUS transducers was fabricated on a wearable sleeve, designed to sonicate the posterior and anterior tibial arteries (and their collaterals) at the calf level.

View Article and Find Full Text PDF

Transcutaneous auricular vagus nerve stimulation attenuates stroke-heart syndrome: The role of parasympathetic activity.

Exp Neurol

March 2025

Department of Anesthesiology, the Key Laboratory of Anesthesiology and Intensive Care Research of Heilongjiang Province, Second Affiliated Hospital of Harbin Medical University, Harbin, China. Electronic address:

Stroke induces cardiac dysfunction, which increases poststroke mortality and morbidity. An imbalance in the autonomic nervous system resulting from brain injury may serve as the underlying mechanism. The present study investigated whether transcutaneous auricular vagus nerve stimulation (taVNS) attenuates poststroke cardiac dysfunction by activating the parasympathetic nervous system.

View Article and Find Full Text PDF
Article Synopsis
  • - Low-intensity pulsed ultrasound (LIPUS) and transcutaneous carbon monoxide (CO) therapy were tested in rats to determine if their combined use would enhance fracture healing more effectively than using either treatment alone.
  • - The study created femoral shaft fractures in rats and divided them into four groups: combination (LIPUS + CO), LIPUS only, CO only, and a control group, treating them regularly for four weeks and assessing bone healing through various methods.
  • - Results showed that the combination group had significantly better fracture healing scores, higher vascular density, and increased gene expression related to bone growth compared to the control and single therapy groups at multiple time points throughout the study.
View Article and Find Full Text PDF
Article Synopsis
  • Osteoarthritis (OA) impacts 528 million people worldwide, mainly affecting knee and hip joints, particularly in women over 55, and creates significant economic challenges, while the effectiveness of physiotherapy methods for pain management remains uncertain.
  • A systematic review of 23 Randomized Controlled Trials investigated various therapeutic modalities (like ultrasound and electrical stimulation) and revealed that 15 out of 30 protocols achieved meaningful pain reduction, yet no distinct advantages among the different methods were found.
  • The study recommends a comprehensive treatment approach, starting with transcutaneous electrical nerve stimulation and continuing with ultrasound and deep microwave diathermy, while also suggesting a careful evaluation of spinal cord nerve stimulation for hip OA patients.
View Article and Find Full Text PDF

Objective: Low-intensity histotripsy (LIH) is a novel and safe technique for tissue ablation. This study aimed to explore the effects of LIH on canine prostate tissue and identify the degree of acute injury to the gland.

Methods: We constructed and evaluated two types of acoustically responsive droplet (ARD) emulsions using either perfluoropentane (PFP) with a lipid shell or perfluoromethyl-cyclopentane (PFMCP) with lauromacrogol (L) injection.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!