The growing threat of an influenza pandemic presents a unique challenge to healthcare workers, emergency responders, and the civilian population. The Occupational Safety and Health Administration (OSHA) recommends National Institute for Occupational Safety and Health (NIOSH)-approved respirators to provide protection against infectious airborne viruses in various workplace settings. The filtration efficiency of selected NIOSH-approved particulate N95 and P100 filtering facepiece respirators (FFRs) and filter cartridges was investigated against the viable MS2 virus, a non-pathogenic bacteriophage, aerosolized from a liquid suspension. Tests were performed under two cyclic flow conditions (minute volumes of 85 and 135 L/min) and two constant flow rates (85 and 270 L/min). The mean penetrations of viable MS2 through the N95 and P100 FFRs/cartridges were typically less than 2 and 0.03%, respectively, under all flow conditions. All N95 and P100 FFR and cartridge models assessed in this study, therefore, met or exceeded their respective efficiency ratings of 95 and 99.97% against the viable MS2 test aerosol, even under the very high flow conditions. These NIOSH-approved FFRs and particulate respirators equipped with these cartridges can be anticipated to achieve expected levels of protection (consistent with their assigned protection factor) against airborne viral agents, provided that they are properly selected, fitted, worn, and maintained.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7196694 | PMC |
http://dx.doi.org/10.1080/15459624.2013.818228 | DOI Listing |
Am J Infect Control
February 2024
National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, Pittsburgh, PA.
Background: A major concern among health care experts is a shortage of N95 filtering facepiece respirators during a pandemic. If the supply of N95 filtering facepiece respirators becomes limited, reusable elastomeric half-mask respirators (EHMRs) may be used to protect health care workers. The focus of this study was to evaluate the effects on the filter performance of wiping decontamination for EHMR P100 filter cartridges.
View Article and Find Full Text PDFJ Psychiatry Neurosci
May 2023
From the Centre Psychothérapique de Nancy, Pôle Hospitalo-Universitaire de Psychiatrie d'Adultes du Grand Nancy, Laxou, France (Remy, Bernardin, Krieg, Schwan, Schwitzer, Laprévote); the INSERM U1114, Fédération de Médecine Translationnelle de Strasbourg, Département de Psychiatrie, Centre Hospitalier Régional Universitaire de Strasbourg, Strasbourg, France (Remy, Bernardin, Krieg, Laprévote); the Centre Psychothérapique de Nancy, Pôle Universitaire de Psychiatrie de l'Enfant et de l'Adolescent, Laxou, France (Ligier); the Université de Lorraine, EA 4360 APEMAC, Equipe MICS, Nancy, France (Ligier); the Université de Lorraine, CNRS, CRAN, UMR 7039, Vandœuvre-lès-Nancy, France (Maillard); the Service de Neurologie, Centre Hospitalier Régional Universitaire de Nancy, Nancy, France (Maillard); the Université de Lorraine, IADI, INSERM U1254, Vandœuvre-lès-Nancy, France (Schwan, Schwitzer); BioSerenity, 47 Boulevard de l'Hôpital, ICM-IPEPS, Paris, France (Remy)
Background: Electrophysiological impairments in the magnocellular visual system have been reported among patients with schizophrenia, but previous theories proposed that these deficits may begin in the retina. We therefore sought to evaluate the potential contribution of the retina by comparing retinal and cortical visual electrophysiological impairments between patients with schizophrenia and healthy controls.
Methods: We recruited patients with schizophrenia and age- and sex-matched healthy controls.
Doc Ophthalmol
April 2023
Clinical and Academic Department of Ophthalmology, Great Ormond Street Hospital for Children NHS Foundation Trust, Great Ormond Street, London, WC1N 3AJ, England, UK.
Introduction: Visual electrophysiology tests require the use of precise and calibrated visual display units (VDUs). Existing VDUs for presenting structured stimuli are now mostly obsolete, with modern solutions limited or unsuitable for clinical testing. Digital light processing (DLP) laser projectors have recently become commercially available and this study aimed to assess their suitability as VDUs for visual electrophysiology testing.
View Article and Find Full Text PDFDiagnostics (Basel)
December 2022
IRCCS-Fondazione Bietti, Via Livenza 1, 00198 Rome, Italy.
Friedreich’s ataxia (FRDA) is a rare autosomal recessive neurodegenerative disorder due to the homozygous pathological expansion of guanine-adenine-adenine (GAA) triplet repeats in the first intron of the FXN gene, which encodes for the mitochondrial protein frataxin. In the visual system, the typical manifestations are ocular motility abnormality, optic neuropathy, and retinopathy. Despite the evidence of ophthalmological impairment in FRDA patients, there is a lack of information about the morpho-functional condition of the retina and of the optic pathways in healthy heterozygous carriers of Friedreich’s ataxia (C-FRDA).
View Article and Find Full Text PDFFront Neurol
October 2022
Eye Hospital, University Medical Centre Ljubljana, Ljubljana, Slovenia.
Background: We present the disease course and long-term follow-up of two patients who were phenotypically diagnosed with atypical Leber Hereditary Optic Neuropathy (LHON) 14 and 12 years ago, respectively, whereby whole exome sequencing revealed recently described recessive DNAJC30:c.152G>A 152 A>G (p.Tyr51Cys) homozygous pathogenic variant with significant spontaneous visual acuity recovery in one.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!