Anesthesia through an intraosseous line using an 18-gauge intravenous needle for emergency pediatric surgery.

J Clin Anesth

Department of Pediatric and Neonatal Anesthesia, Children's Welfare Teaching Hospital, Medical City, Baghdad, Iraq. Electronic address:

Published: September 2013

Study Objective: To describe the success and complication rate of intraosseous (IO) access for delivery of anesthesia with the use of an 18-gauge (G) intravenous (IV) needle.

Design: Prospective study.

Setting: Children's Welfare Teaching Hospital, Baghdad, Iraq.

Patients: 300 critically ill infants and toddlers, age 3 weeks to 16 months, requiring emergency surgery for intra-abdominal or pelvic conditions, in whom peripheral or central access was not obtainable. Patients presented for surgery between 2007 and 2010.

Interventions: In 26 patients, the IO catheter was established when peripheral access was not obtained at the outset of surgery; in 4 patients standard peripheral vascular access failed during the surgical procedure and IO access was obtained. An 18-G IV needle was placed into the proximal tibia and attached to an extension set with a 3-way stopcock to deliver anesthesia.

Main Results: For 26 critically ill children and 4 other children, IV access failed during delivery of anesthesia; vascular access was successfully obtained within minutes in all 30 infants (100%) using the intraosseous route. Ninety percent (27/30) of patients awoke immediately postoperatively in good condition; 10% (3/30) went to the pediatric intensive care unit (PICU) for further care due to their critical preoperative condition. Complications associated with use of the IO route were considered minor (3/30 pts [10%]) and included extravasation of fluid in two cases and cellulitis in one.

Conclusion: The IO route provided for rapid delivery of anesthesia, induction, and maintenance in this series of critically ill infants undergoing emergency surgery when other vascular access routes failed. Few complications were noted. Intraosseous access was achieved through a simple technique using an 18-gauge IV needle.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jclinane.2013.03.013DOI Listing

Publication Analysis

Top Keywords

delivery anesthesia
12
critically ill
12
vascular access
12
access
9
18-gauge intravenous
8
intraosseous access
8
ill infants
8
emergency surgery
8
access failed
8
surgery
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!