Purpose: CT neuroperfusion examinations are capable of delivering high radiation dose to the skin or lens of the eyes of a patient and can possibly cause deterministic radiation injury. The purpose of this study is to: (a) estimate peak skin dose and eye lens dose from CT neuroperfusion examinations based on several voxelized adult patient models of different head size and (b) investigate how well those doses can be approximated by some commonly used CT dose metrics or tools, such as CTDIvol, American Association of Physicists in Medicine (AAPM) Report No. 111 style peak dose measurements, and the ImPACT organ dose calculator spreadsheet.
Methods: Monte Carlo simulation methods were used to estimate peak skin and eye lens dose on voxelized patient models, including GSF's Irene, Frank, Donna, and Golem, on four scanners from the major manufacturers at the widest collimation under all available tube potentials. Doses were reported on a per 100 mAs basis. CTDIvol measurements for a 16 cm CTDI phantom, AAPM Report No. 111 style peak dose measurements, and ImPACT calculations were performed for available scanners at all tube potentials. These were then compared with results from Monte Carlo simulations.
Results: The dose variations across the different voxelized patient models were small. Dependent on the tube potential and scanner and patient model, CTDIvol values overestimated peak skin dose by 26%-65%, and overestimated eye lens dose by 33%-106%, when compared to Monte Carlo simulations. AAPM Report No. 111 style measurements were much closer to peak skin estimates ranging from a 14% underestimate to a 33% overestimate, and with eye lens dose estimates ranging from a 9% underestimate to a 66% overestimate. The ImPACT spreadsheet overestimated eye lens dose by 2%-82% relative to voxelized model simulations.
Conclusions: CTDIvol consistently overestimates dose to eye lens and skin. The ImPACT tool also overestimated dose to eye lenses. As such they are still useful as a conservative predictor of dose for CT neuroperfusion studies. AAPM Report No. 111 style measurements are a better predictor of both peak skin and eye lens dose than CTDIvol and ImPACT for the patient models used in this study. It should be remembered that both the AAPM Report No. 111 peak dose metric and CTDIvol dose metric are dose indices and were not intended to represent actual organ doses.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3965341 | PMC |
http://dx.doi.org/10.1118/1.4816652 | DOI Listing |
Indian J Ophthalmol
January 2025
Department of Ophthalmology, University of Washington, Seattle, WA, USA.
Purpose: To characterize visual outcomes in Zone I and II open globe injuries with lens involvement.
Setting: Level 1 Trauma Center Hospital, Seattle WA.
Design: Retrospective case series.
Cont Lens Anterior Eye
December 2024
Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, Queensland, Australia. Electronic address:
Front Med (Lausanne)
December 2024
Section of Neurobiology of the Eye, Ophthalmic Research Institute, University of Tübingen, Tübingen, Germany.
Purpose: Changes in choroidal thickness (ChT) are proposed to predict myopia development but evidence is mixed. We investigated time courses of choroidal responses, following different types of dynamic artificial stimulation in chicks with and without spectacle lenses, as well as changes in retinal dopamine metabolism and expression of candidate genes.
Methods: Chicks were kept in an arena surrounded by computer monitors presenting dynamic checkerboard fields of small, medium and large size.
Clin Ophthalmol
December 2024
Alcon Vision LLC, Fort Worth, TX, USA.
Purpose: To compare the refractive prediction accuracy of the Optiwave Refractive Analysis (ORA) SYSTEM with the Barrett True-K (BTK) formula in calculating intraocular lens (IOL) power in eyes that underwent cataract surgery after previous myopic photorefractive keratectomy (PRK) or laser-assisted in situ keratomileusis (LASIK).
Methods: This retrospective study evaluated patients aged ≥22 years with prior myopic PRK or LASIK who underwent unilateral or bilateral cataract removal and monofocal IOL implantation using the ORA SYSTEM at 177 sites in the United States. Two datasets were analyzed: All Eyes (ie, all eligible eyes) and First Surgery Eyes (ie, each patient's first implanted eye).
BMC Ophthalmol
December 2024
National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 3250027, China.
Objectives: To analyze the influence of daily activity-related factors associated with COVID-19 infection on the occurrence of acute angle closure (AAC).
Methods: A multicenter hospital-based study was conducted at 23 ophthalmic centers in 17 provincial-level regions across China to recruit patients with confirmed AAC during the post-lockdown time of COVID-19 (P-TOC) from Dec 7, 2022, to Jan 17, 2023, and three lockdown time of COVID-19 (TOC) periods, which included the TOC-2022 (Sep 7, 2022 - Dec 6, 2022), TOC-2021(Sep 7, 2021 - Jan 6, 2022) and TOC-2020 (Sep 7, 2020 - Jan 6, 2021). Patient information, including demographic, a questionnaire on daily activity changes during the AAC period, COVID-19 history, and eye examination results, was collected.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!