The 30 keV lithium beam diagnostic on DIII-D is suitable to measure both the radial electron density and poloidal magnetic field profiles in the pedestal. The refurbished system features a new setup to measure the Doppler shift allowing accurate alignment of the spectral filters. The injector has been optimized to generate a stable lithium neutral beam with a current of I = 15-20 mA and a diameter of 1.9 ± 0.1 cm measured by beam imaging. The typical temporal resolution is Δt = 1-10 ms and the radial resolution of ΔR = 5 mm is given by the optical setup. A new analysis technique based on fast Fourier transform avoids systematic error contributions from the digital lock-in analysis and accounts intrinsically for background light correction. Latest upgrades and a detailed characterization of the system are presented. Proof-of-principle measurements of the poloidal magnetic field with a statistical error of typically 2% show a fair agreement with the predictions modeled with the Grad-Shafranov equilibrium solver EFIT within 4%.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.4816824DOI Listing

Publication Analysis

Top Keywords

lithium beam
8
beam diagnostic
8
diagnostic diii-d
8
poloidal magnetic
8
magnetic field
8
status characterization
4
characterization lithium
4
beam
4
diii-d 30 kev
4
30 kev lithium
4

Similar Publications

We propose and demonstrate integrated photonic crystal (PhC) beam splitters based on X-cut thin film lithium niobate (TFLN). Its working principle is based on bandgap guidance and total reflection in the PhC slab. We designed two structures: one features a triangular lattice, while the other exhibits a tetragonal lattice.

View Article and Find Full Text PDF

Variable relative biological effectiveness (RBE) of carbon radiotherapy may be calculated using several models, including the microdosimetric kinetic model (MKM), stochastic MKM (SMKM), repair-misrepair-fixation (RMF) model, and local effect model I (LEM), which have not been thoroughly compared. In this work, we compared how these four models handle carbon beam fragmentation, providing insight into where model differences arise. Monoenergetic and spread-out Bragg peak carbon beams incident on a water phantom were simulated using Monte Carlo.

View Article and Find Full Text PDF

Growth of lithium whiskers or dendrites is the major obstacle towards safe and stable utilization of lithium metal anodes in rechargeable batteries. In this study, we look deeper into the mechanism of lithium electrodeposition. We find that before lithium whisker or dendrite nucleation occurs, lithium is deposited into the grain boundaries of the metal electrode, which we directly observed in the focused ion beam cross-sections of the lithium electrode.

View Article and Find Full Text PDF

Terahertz (THz) parametric detection is a highly sensitive method that upconverts a THz wave into a near-infrared beam for detection. Lithium niobate has primarily been used as the nonlinear optical crystal in this approach. However, the frequency band with high parametric gain is limited, leading to increasing interest in other nonlinear optical crystals.

View Article and Find Full Text PDF

High degree of fluorination for ether electrolytes has resulted in improved cycling stability of lithium metal batteries due to stable solid electrolyte interphase (SEI) formation and good oxidative stability. However, the sluggish ion transport and environmental concerns of high fluorination degree drive the need to develop less fluorinated structures. Here, we depart from the traditional ether backbone and introduce bis(2-fluoroethoxy)methane (F2DEM), featuring monofluorination of the acetal backbone.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!