Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: To evaluate the properties of experimental infiltrant blends by comparing them with the commercial infiltrant Icon(®) and penetration homogeneity into enamel caries lesions.
Methods: Groups were set up as follows: G1 (TEGDMA 100%); G2 (TEGDMA 80%, Ethanol 20%); G3 (TEGDMA 80%, HEMA 20%); G4 (TEGDMA 75%, BisEMA 25%); G5 (TEGDMA 60%, BisEMA 20%, Ethanol 20%); G6 (TEGDMA 60%, BisEMA 20%, HEMA 20%); G7 (TEGDMA 75%, UDMA 25%); G8 (TEGDMA 60%, UDMA 20%, Ethanol 20%); G9 (TEGDMA 60%, UDMA 20%, HEMA 20%) and Icon(®). Ten specimens were comprised by each group for the following tests (n=10): degree of conversion (DC), elastic modulus (EM), Knoop hardness (KH), and softening ratio (SR). Infiltrant penetration was evaluated using confocal microscopy (CLSM). Data were subjected to two-way ANOVA and a Tukey's test (5%). Data comparing experimental materials and Icon(®) were analysed using ANOVA and Dunnett's test (5%).
Results: The highest DC values were found in G1, G7, G8, and G9. The lowest DC values were found in G2, G4, G5, and G6. EM and KHN were significantly lower in HEMA and with ethanol addition for all blends, except for G9. There was no significant difference among the groups regarding SR, and it was not possible to take KHN readings of G2, G5, and G8 after storage. There was no significant difference among groups for infiltrant penetration into enamel lesions.
Conclusions: The addition of hydrophobic monomers and solvents into TEGDMA blends affected DC, EM, and KHN. UDMA added to TEGDMA resulted in an increase in DC, EM, and KHN. Overall, solvents added to monomer blends resulted in decreased properties. The addition of hydrophobic monomers and solvents into TEGDMA blends does not improve the penetration depth of the infiltrants.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jdent.2013.08.019 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!