A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Online NMR and HPLC as a reaction monitoring platform for pharmaceutical process development. | LitMetric

Online NMR and HPLC as a reaction monitoring platform for pharmaceutical process development.

Anal Chem

Analytical Research and Development, Pfizer Worldwide Research and Development , Eastern Point Road, Groton, Connecticut 06340, United States.

Published: October 2013

Detector response is not always equivalent between detectors or instrument types. Factors that impact detector response include molecular structure and detection wavelength. In liquid chromatography (LC), ultraviolet (UV) is often the primary detector; however, without determination of UV response factors for each analyte, chromatographic results are reported on an area percent rather than a weight percent. In extreme cases, response factors can differ by several orders of magnitude for structurally dissimilar compounds, making the uncalibrated data useless for quantitative applications. While impurity reference standards are normally used to calculate UV relative response factors (RRFs), reference standards of reaction mixture components are typically not available during route scouting or in the early stages of process development. Here, we describe an approach to establish RRFs from a single experiment using both online nuclear magnetic resonance (NMR) and LC. NMR is used as a mass detector from which a UV response factor can be determined to correct the high performance liquid chromatography (HPLC) data. Online reaction monitoring using simultaneous NMR and HPLC provides a platform to expedite the development and understanding of pharmaceutical reaction processes. Ultimately, the knowledge provided by a structurally information rich technique such as NMR can be correlated with more prevalent and mobile instrumentation [e.g., LC, mid-infrared spectrometers (MIR)] for additional routine process understanding and optimization.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac402382dDOI Listing

Publication Analysis

Top Keywords

detector response
12
response factors
12
nmr hplc
8
reaction monitoring
8
process development
8
liquid chromatography
8
reference standards
8
response
6
online nmr
4
reaction
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!