Improvement of atopic dermatitis severity after reducing indoor air pollutants.

Ann Dermatol

Department of Dermatology, Kangnam Sacred Heart Hospital, College of Medicine, Hallym University, Seoul, Korea.

Published: August 2013

Background: Recent epidemiologic studies have shown that environmental contaminants such as air pollution and tobacco smoke play an important role in the pathophysiology of atopic dermatitis (AD).

Objective: The aim of this study was to evaluate the relationship between the severity of AD and indoor air pollution.

Methods: The study population consisted of 425 children from 9 kindergartens, Korea. The authors surveyed the prevalence of AD and evaluated disease severity by the eczema area and severity index (EASI) score and investigator's global assessment (IGA). After measuring indoor air pollution, a program to improve indoor air quality was conducted in 9 kindergartens. Seven months later, the prevalence and disease severity were evaluated.

Results: The initial prevalence of AD was 8% and the mean EASI score was 2.37. The levels of particulate material 10 (PM10) and carbon dioxide (CO2) were higher in some kindergartens compared to the normal values. Subsequent to the completion of the indoor air quality improvement program, the mean PM10 level was significantly decreased from 182.7 to 73.4 µg/m(3). After the completion of the program, the prevalence of AD and the mean EASI were decreased, and the changes were both statistically significant. The mean number of hospital visits decreased from 1.3 per month during the first survey to 0.7 per month during the second survey, which was statistically significant.

Conclusion: Indoor air pollution could be related to AD. The reduction of PM10 through improving indoor air quality should be considered in kindergartens and schools in order to prevent and relieve AD in children.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3756192PMC
http://dx.doi.org/10.5021/ad.2013.25.3.292DOI Listing

Publication Analysis

Top Keywords

indoor air
28
air pollution
12
air quality
12
atopic dermatitis
8
air
8
disease severity
8
easi score
8
prevalence easi
8
indoor
7
severity
5

Similar Publications

Efficient CO2 capture at concentrations between 400-2000 ppm is essential for maintaining air quality in a habitable environment and advancing carbon capture technologies. This study introduces NICS-24 (National Institute of Chemistry Structures No. 24), a Zn-oxalate 3,5-diamino-1,2,4-triazolate framework with two distinct square-shaped channels, designed to enhance CO2 capture at indoor-relevant concentrations.

View Article and Find Full Text PDF

Pulmonary function in swimmers exposed to disinfection by-products: a narrative review.

Front Physiol

January 2025

Department of Sport Medicine and Traumatology, Poznan Univeristy of Physical Education, Poznań, Poland.

Swimming produces many psychophysiological effects, including blood, hormonal, enzymatic, pulmonary, cardiovascular and energetic adaptations. However, asthma and allergies are becoming increasingly prevalent medical issues among elite endurance-trained swimmers, where exercise-induced asthma or bronchospasm is frequently reported. Heavy endurance swimming training, especially under adverse conditions, stresses the airway mucosa, leading to inflammatory changes, as observed in induced sputum in competitive swimmers.

View Article and Find Full Text PDF

Airborne Escherichia coli bacteria biosynthesize lipids in response to aerosolization stress.

Sci Rep

January 2025

Aerosol Technology Laboratory, Biological and Agricultural Engineering Department, Texas A&M University, College Station, TX, 77843, USA.

Gram-negative bacteria pose an increased threat to public health because of their ability to evade the effects of many antimicrobials with growing antibiotic resistance globally. One key component of gram-negative bacteria resistance is the functionality and the cells' ability to repair the outer membrane (OM) which acts as a barrier for the cell to the external environment. The biosynthesis of lipids, particularly lipopolysaccharides, or lipooligosaccharides (LPS/LOS) is essential for OM repair.

View Article and Find Full Text PDF

Chemical Transformation of Vaping Emissions under Indoor Atmospheric Aging Processes.

Chem Res Toxicol

January 2025

Department of Environmental Sciences, University of California, Riverside, California 92521, United States.

E-cigarette emissions, which contain a variety of hazardous compounds, contribute significantly to indoor air pollution and raise concerns about secondhand exposure to vaping byproducts. Compared to fresh vape emissions, our understanding of chemically aged products in indoor environments remains incomplete. Terpenes are commonly used as flavoring agents in e-liquids, which have the ability to react with the dominant indoor oxidant ozone (O) to produce reactive oxygenated byproducts and result in new particle formation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!