Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1161/CIRCULATIONAHA.112.000170 | DOI Listing |
Int J Hematol
January 2025
Associated Department With Mie Graduate School of Medicine, Mie Prefectural General Medical Center, Yokkaichi, Japan.
This study discusses disseminated intravascular coagulation (DIC) associated with solid cancers and various vascular abnormalities, both of which generally exhibit chronic DIC patterns. Solid cancers are among the most significant underlying diseases that induce DIC. However, the severity, bleeding tendency, and progression of DIC vary considerably depending on the type and stage of the cancer, making generalization difficult.
View Article and Find Full Text PDFBJS Open
December 2024
Department of Cardiothoracic Surgery, Liverpool Heart and Chest Hospital, Liverpool, UK.
Background: Acute type A aortic dissection is a life-threatening clinical emergency that necessitates immediate surgical intervention with an estimated mortality rate of approximately 1-2% per hour. When complicated by malperfusion, the perioperative mortality rate is reported to be increased by up to 39%. Malperfusion can affect many vascular beds with varying incidence and severity, resulting in coronary, cerebral, visceral, peripheral, renal or spinal malperfusion.
View Article and Find Full Text PDFBackground: The use of mechanical circulatory support devices for high-risk percutaneous coronary intervention (PCI) has increased over the past decade despite limited data of benefit. We sought to examine the association between intravascular microaxial left ventricular assist device (LVAD) versus intra-aortic balloon pump use in patients without cardiogenic shock (CS) undergoing PCI.
Methods And Results: This retrospective study analyzed claims data from a large, insured population who underwent PCI without CS from April 1, 2016 to July 31, 2022.
Ann Thorac Surg Short Rep
December 2024
Division of Cardiac Surgery, Inova Heart and Vascular Institute, Inova Health Systems, Falls Church, Virginia.
Background: DeBakey type I aortic dissections (AD) are most frequently treated with hemiarch repair. A subset of patients demonstrates persistent distal end-organ ischemia secondary to persistent true lumen (TL) compression. We describe the use of bare metal stent grafting across the residual arch dissection with the Zenith Dissection Endovascular Stent (ZDES, Cook Medical) in 7 patients with type I AD that was repaired in a hemiarch configuration with a compromised distal TL and organ malperfusion.
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
December 2024
Duke University Medical Center, Durham, North Carolina.
Background: Direct mechanical ventricular actuation (DMVA) with the Anstadt cup is effective for non-blood-contacting biventricular support. Pneumatic regulation of a silicone device augments ventricular pump function. Vacuum attachment facilitates diastolic augmentation critical for biventricular support.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!