The study was performed on 22 patients with congenital heart valve defects after hypothermic cardiopulmonary bypass surgery. Transcutaneous and arterial pO2 and pCO2 have been measured at different stages of investigation. Nonpulsatile flow was applied to 10 patients and pulsatile flow--to 12 patients. Pulsatile pressure was maintained at about 30 mmHg. Transcutaneous index, carbon dioxide gradient and transcutaneous oxygen shunt have been calculated. Perfusion caused a decrease in transcutaneous pO2 and transcutaneous index, as well as an increase in transcutaneous O2 shunt. The use of non-pulsatile flow caused the most marked peripheral vasoconstriction. Transcutaneous index demonstrates that peripheral circulation decrease in pulsatile flow is 3 times lower than in non-pulsatile flow. Calculation of transcutaneous index and O2 shunt based on transcutaneous pO2 and pCO2 values can characterize peripheral circulation prior to, during and following perfusion.

Download full-text PDF

Source

Publication Analysis

Top Keywords

transcutaneous po2
12
po2 pco2
12
transcutaneous
10
patients pulsatile
8
transcutaneous shunt
8
non-pulsatile flow
8
peripheral circulation
8
[study peripheral
4
peripheral blood
4
blood circulation
4

Similar Publications

Central sleep apneas (CSA) can occur de novo at high-altitude in individuals without sleep-disordered breathing at low altitude. These apneas are usually brief, lasting only 5-15 s. This report presents the first documented case of a man experiencing extreme altitude-induced CSA lasting more than 100 s in the absence of any sleep breathing disorder in normoxia.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the effects of wearing N95 masks compared to loop/surgical masks on healthcare workers during long shifts, focusing on symptoms like fatigue and blood gas levels.
  • It involved a survey and measurements of carbon dioxide and oxygen levels before and after shifts, with 39 subjects participating.
  • Results indicated that those wearing N95 masks reported significantly higher fatigue levels, but no meaningful differences were found in arterial blood gas parameters between the two mask types.
View Article and Find Full Text PDF

Importance: Peripheral artery disease (PAD) in diabetes may lead to diabetic foot ulcer and lower-extremities amputation. Glucagon-like peptide 1 receptor agonists have proven cardiovascular benefits in trials of people with type 2 diabetes at high cardiovascular risk.

Objective: To examine the effect of liraglutide on peripheral perfusion measured as peripheral transcutaneous oxygen pressure (TcPo2) in individuals with type 2 diabetes and PAD.

View Article and Find Full Text PDF

Purpose: Electron spin resonance (ESR) is used to measure oxygen partial pressure (pO) in biological media with many clinical applications. Traditional clinical ESR involves large magnets that encompass the subject of measurement. However, certain applications might benefit from a scanner operating within local static magnetic fields.

View Article and Find Full Text PDF

Calculation of Tissue Oxygenation via an Inverse Boundary Problem for Transcutaneous Oxygenation Wearable Applications.

ACS Meas Sci Au

August 2023

Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Charlestown, Massachusetts 02129, United States.

In this article, we present a toolset to fully leverage a previously developed transcutaneous oxygenation monitor (TCOM) wearable technology to accurately measure skin oxygenation values. We describe numerical models and experimental characterization techniques that allow for the extraction of precise tissue oxygenation measurements. The numerical model is based on an inverse boundary problem of the parabolic equation with Dirichlet boundary conditions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!