Finding in vitro eye irritation testing alternatives to animal testing such as the Draize eye test, which uses rabbits, is essential from the standpoint of animal welfare. It has been developed a reconstructed human corneal epithelial model, the LabCyte CORNEA-MODEL, which has a representative corneal epithelium-like structure. Protocol optimization (pre-validation study) was examined in order to establish a new alternative method for eye irritancy evaluation with this model. From the results of the optimization experiments, the application periods for chemicals were set at 1min for liquid chemicals or 24h for solid chemicals, and the post-exposure incubation periods were set at 24h for liquids or zero for solids. If the viability was less than 50%, the chemical was judged to be an eye irritant. Sixty-one chemicals were applied in the optimized protocol using the LabCyte CORNEA-MODEL and these results were evaluated in correlation with in vivo results. The predictions of the optimized LabCyte CORNEA-MODEL eye irritation test methods were highly correlated with in vivo eye irritation (sensitivity 100%, specificity 80.0%, and accuracy 91.8%). These results suggest that the LabCyte CORNEA-MODEL eye irritation test could be useful as an alternative method to the Draize eye test.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.tiv.2013.08.008 | DOI Listing |
Biol Pharm Bull
July 2023
Department of Biosciences and Bioinformatics, Kyushu Institute of Technology.
We aimed to investigate eye damage caused by ocular iontophoresis (IP) based on an in vitro eye irritation test using a reconstructed human corneal cell. In this study, the LabCyte CORNEA-MODEL was selected as the reconstructed corneal cell. The test procedure was performed according to Test Guideline No.
View Article and Find Full Text PDFToxicol In Vitro
February 2021
Department of Chemical, Energy and Environmental Engineering, Faculty of Environmental and Urban Engineering, Kansai University, Japan.
Concerns regarding animal welfare have led to the need for alternatives to animal eye irritation tests. The reconstructed human cornea-like epithelium (RhCE) test is described in the OECD TG 492 as an alternative to animal eye irritation tests. However, the accuracy and labor investment of this method can be improved if the results can be predicted before the experiment.
View Article and Find Full Text PDFToxicol In Vitro
December 2013
R&D Department, Japan Tissue Engineering Co., Ltd., 6-209-1 Miyakitadori, Gamagori, Aichi 443-0022, Japan. Electronic address:
Finding in vitro eye irritation testing alternatives to animal testing such as the Draize eye test, which uses rabbits, is essential from the standpoint of animal welfare. It has been developed a reconstructed human corneal epithelial model, the LabCyte CORNEA-MODEL, which has a representative corneal epithelium-like structure. Protocol optimization (pre-validation study) was examined in order to establish a new alternative method for eye irritancy evaluation with this model.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!