Statement Of Problem: Different parameters are used in the literature to describe translucency, making it difficult for clinicians to find clear information on ceramic translucency and compare studies.

Purpose: The purpose of this study was to assess the correlation between the contrast ratio (CR) and translucency parameter (TP) when the translucency of different types of ceramic systems is compared.

Material And Methods: Disks 13 mm in diameter and 0.7 mm thick were fabricated for the following materials (n=5): VITA VM9, VITA PM9, IPS Empress CAD, IPS e.max CAD, IPS e.maxPress, and Lava Zirconia. VITA VM9 served as positive control, while Lava Zirconia served as negative control. The luminous reflectance (Y) and color coordinates (CIE L* a* b*) of the specimens were measured with a tristimulus colorimeter. The CR (CR=Yb/Yw) was calculated from the reflectance of the light of the material on a black backing (Yb) to the reflectance on a white backing (Yw). The TP (TP=[(Lb*Lw*)(2+)(ab*-aw*)(2+)(bb*-bw*)(2) ](1/2)) was calculated from the color difference of the material on a black versus a white background. One-way ANOVA based on ranked data and the Pearson and Spearman rank correlation tests were used to analyze the data (α=.05).

Results: A significant correlation between CR and TP was found when all specimens were included (P<.001). The coefficient of -0.99 indicated a strong decreasing relationship between the 2 variables.

Conclusions: Either CR or TP can be used to evaluate the relative translucency of ceramic systems.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2013.06.008DOI Listing

Publication Analysis

Top Keywords

contrast ratio
8
vita vm9
8
cad ips
8
lava zirconia
8
material black
8
translucency
5
ceramic materials
4
materials porcelain
4
porcelain veneers
4
correlation
4

Similar Publications

Multi-Energy Evaluation of Image Quality in Spectral CT Pulmonary Angiography Using Different Strength Deep Learning Spectral Reconstructions.

Acad Radiol

December 2024

Radiomics and Augmented Intelligence Laboratory (RAIL), Department of Radiology and the Norman Fixel Institute for Neurological Diseases, University of Florida College of Medicine, Gainesville, FL (M.H-S., H.S.S., A.G.R., S.E.M., J.C.P., E.Y.A., B.H., R.F.); Department of Radiology, University of Florida College of Medicine, Gainesville, FL (M.H-S., H.S.S., A.G.R., J.C.P., E.Y.A., B.H., R.F.); Division of Medical Physics, University of Florida College of Medicine, Gainesville, FL (R.F.); Department of Neurology, Division of Movement Disorders, University of Florida College of Medicine, Gainesville, FL (R.F.); Department of Otolaryngology - Head and Neck Surgery, McGill University, Montreal, Quebec, Canada (R.F.); Department of Radiology, AdventHealth Medical Group, Maitland, FL (R.F.). Electronic address:

Rationale And Objectives: To evaluate and compare image quality of different energy levels of virtual monochromatic images (VMIs) using standard versus strong deep learning spectral reconstruction (DLSR) on dual-energy CT pulmonary angiogram (DECT-PA).

Materials And Methods: A retrospective study was performed on 70 patients who underwent DECT-PA (15 PE present; 55 PE absent) scans. VMIs were reconstructed at different energy levels ranging from 35 to 200 keV using standard and strong levels with deep learning spectral reconstruction.

View Article and Find Full Text PDF

Long-acting injectable in situ forming implants: Impact of polymer attributes and API.

Int J Pharm

December 2024

Department of Pharmaceutical Sciences, University of Connecticut, Storrs, CT 06269, USA. Electronic address:

Poly(DL-lactide-co-glycolide) (PLGA) and N-methyl-2-pyrrolidone (NMP)-based in situ forming implants are liquid formulations that solidify through phase separation following injection into the body. Drug is dissolved or suspended in the final formulation liquid prior to injection. Depending on the polymers used, the depots formed can deliver drug over different periods of time.

View Article and Find Full Text PDF

Bullet characterization using Photon-Counting detector CT: A phantom study with intact bullets.

Eur J Radiol

December 2024

Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre+, PO Box 5800, 6202 AZ Maastricht, the Netherlands; Mental Health and Sciences (MHeNs) Research Institute, Maastricht University, PO Box 616, 6200 MD Maastricht, the Netherlands.

Objectives: Photon-counting detector CT (PCD-CT) is expected to substantially improve and expand CT-imaging applicability due to its intrinsic spectral capabilities, increased spatial resolution, reduced electronic noise, and improved image contrast. The current study aim is to evaluate PCD-CT efficacy in characterizing bullets based on their dimensions, shape, and material composition.

Materials And Methods: This is an observational phantom study examining 11 unfired, intact bullets of various common calibers, placed in ballistic gelatin.

View Article and Find Full Text PDF

Development and stability of W1/O/W2 double emulsions stabilized by food-grade nanoparticles.

Food Chem

December 2024

Nano-biotechnology Key Laboratory of Hebei Province, State Key Laboratory of Metastable Materials Science and Technology, School of Environmental and Chemical Engineering, Yanshan University, Qinhuangdao 066004, PR China. Electronic address:

This study presented the well stable W1/O/W2 double emulsions stabilized by food-grade nanoparticles. Firstly, the nanoparticles were prepared based on soybean protein isolate and Hohenbuehelia serotina polysaccharides by physical effects, which had the elliptical morphology and the average particle size of 639.96 nm.

View Article and Find Full Text PDF

Objective: To compare the translucency and contrast ratio of 13 different resin based restorative materials and to evaluate the effect of 2 different bleaching methods on the translucency and contrast ratio of these materials.

Methods: In this study, a total of 260 samples were prepared, 20 from each of 13 different dimethacrylate-based restorative materials. Then, each material group was divided into 4 subgroups.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!