An amperometric biosensor for the determination of L-lysine based on L-lysine-α-oxidase immobilized by co-crosslinking on a platinum electrode previously modified by an overoxidized polypyrrole film is described. The optimization of experimental parameters, such as pH and flow rate, permitted to minimize significantly substrate interferences even using a low specific, commercial enzyme. The relevant biases introduced in the measurement of lysine were just about 1% for L-arginine, L-histidine and L-ornithine, roughly 4% for L-phenylalanine and L-tyrosine. The developed approach allowed linear lysine responses from 0.02 mM up to 2 mM with a sensitivity of 41 nA/(mM × mm(2)) and a detection limit of 4 μM (S/N=3). No appreciable loss in lysine sensitivity was observed up to about 40 days. Allowing polypyrrole layer to remove interference from electroactive compounds, the present method revealed suitable to detect L-lysine in a pharmaceutical and cheese sample, showing a good agreement with the expected values.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.aca.2013.07.036 | DOI Listing |
Sci Rep
January 2025
Department of Chemistry, Amrita School of Physical Sciences Coimbatore, Amrita Vishwa Vidyapeetham, Coimbatore, 641112, India.
Sensors (Basel)
December 2024
Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine, 03680 Kyiv, Ukraine.
This work presents the development of an amperometric biosensor for detecting aspartate aminotransferase (AST) activity in biological fluids using a platinum disk electrode as the working transducer. Optimal concentrations of substrates (aspartate, α-ketoglutarate) and the coenzyme (pyridoxal phosphate) were determined to ensure efficient biosensor operation. A semi-permeable poly-m-phenylenediamine membrane was applied to enhance selectivity against electroactive interferents.
View Article and Find Full Text PDFBiosens Bioelectron
December 2024
Centre for Biomedicine, Hull York Medical School, University of Hull, Hull HU6 7RX, United Kingdom. Electronic address:
Early detection of hepatitis C virus (HCV) infection is crucial for eliminating this silent killer, especially in resource-limited settings. HCV core antigen (HCVcAg) represents a promising alternative to the current "gold standard" HCV RNA assays as an active viremia biomarker. Herein, a highly sensitive electrochemical magneto-immunosensor for the HCVcAg was developed.
View Article and Find Full Text PDFTalanta
December 2024
Department of Chemistry, University of Texas at San Antonio, TX, 78249, USA. Electronic address:
Aminated carbon nanotubes, CNT, were covalently modified with glutardialdehyde (GDI) and the redox dye Azure to form a new electrode material CNT-GDI-Azure (CGA). The nanocomposite of CGA and polysaccharide chitosan was used for the anodic determination of NADH. Compared to conventional carbon and metal electrodes, the CGA electrode drastically lowered the overpotential for NADH oxidation (by > 0.
View Article and Find Full Text PDFBiosensors (Basel)
December 2024
Department of Cogno-Mechatronics Engineering, College of Nanoscience and Nanotechnology, Pusan National University, Busan 46241, Republic of Korea.
Enzyme-based portable amperometric biosensors are precise and low-cost medical devices used for rapid cancer biomarker screening. Sarcosine (Sar) is an ideal biomarker for prostate cancer (PCa). Because human serum and urine contain complex interfering substances that can directly oxidize at the electrode surface, rapid Sar screening biosensors are relatively challenging and have rarely been reported.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!