A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Impedance changes in chronically implanted and stimulated cochlear implant electrodes. | LitMetric

Objectives: Electrode impedance increases following implantation and undergoes transitory reduction with onset of electrical stimulation. The studies in this paper measured the changes in access resistance and polarization impedance in vivo before and following electrical stimulation, and recorded the time course of these changes.

Design: Impedance measures recorded in (a) four cats following 6 months of cochlear implant use, and (b) three cochlear implant recipients with 1.5-5 years cochlear implant experience.

Results: Both the experimental and clinical data exhibited a reduction in electrode impedance, 20 and 5% respectively, within 15-30 minutes of stimulation onset. The majority of these changes occurred through reduction in polarization impedance. Cessation of stimulation was followed by an equivalent rise in impedance measures within 6-12 hours.

Conclusions: Stimulus-induced reductions in impedance exhibit a rapid onset and are evident in both chronic in vivo models tested, even several years after implantation. Given the impedance changes were dominated by the polarization component, these findings suggest that the electrical stimulation altered the electrode surface rather than the bulk tissue and fluid in the cochlea.

Download full-text PDF

Source
http://dx.doi.org/10.1179/1754762813Y.0000000050DOI Listing

Publication Analysis

Top Keywords

cochlear implant
16
electrical stimulation
12
impedance
9
impedance changes
8
electrode impedance
8
polarization impedance
8
impedance measures
8
stimulation
5
changes chronically
4
chronically implanted
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!