Background: Seroma formation is one of the most common complications following abdominoplasty. Fibrin sealant/glue has shown mixed results in seroma prevention when used in a variety of procedures. Limited information is available on its effectiveness during postbariatric abdominoplasty.

Methods: A retrospective chart analysis of 65 consecutive patients who underwent postbariatric abdominoplasty over a course of 16 months by a single surgeon was performed. Two sequential groups either receiving or not receiving fibrin sealant treatment were defined. Seroma formation and initial 24 h drain output volumes were recorded.

Results: Three patients in group 1 (9.1%) receiving fibrin sealant developed seroma. Twelve patients in group 2 (28.1%) not receiving fibrin sealant developed seroma; this was statistically significant (P=0.006). Twenty-four hour drain output was also statistically different, with higher initial output in the fibrin sealant group (222.2 mL versus 140.0 mL; P=0.047).

Conclusion: Fibrin sealant was a useful adjunct during surgical wound closure and significantly decreased seroma formation in patients undergoing postbariatric abdominoplasty.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3433815PMC
http://dx.doi.org/10.1177/229255031202000317DOI Listing

Publication Analysis

Top Keywords

fibrin sealant
24
seroma formation
16
postbariatric abdominoplasty
12
receiving fibrin
12
drain output
8
patients group
8
sealant developed
8
developed seroma
8
fibrin
7
seroma
7

Similar Publications

Retinal graft dislocation managed by repeat autologous retinal transplant for refractory macular hole.

BMJ Case Rep

January 2025

Smt. Kanuri Santhamma Centre for Vitreo Retinal Diseases, Anant Bajaj Retina Institute, LV Prasad Eye Institute, Hyderabad, Telangana, India

A septuagenarian man presented with a visual acuity of hand motions and a large refractory macular hole (MH). We performed an autologous retinal transplant (ART) and covered the graft with fibrin glue without any endotamponade. The autograft was found to have dislocated from the MH when the patient was reviewed 1 week later.

View Article and Find Full Text PDF

Application of fibrin sealant in drain-free transoral endoscopic thyroidectomy vestibular approach.

Tzu Chi Med J

August 2024

Department of Otolaryngology, Head and Neck Surgery, Taichung Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Taichung, Taiwan.

Objective: The transoral endoscopic thyroidectomy vestibular approach (TOETVA) is a minimally invasive technique. This study aimed to compare the safety of TOETVA with fibrin sealant (Tisseel) and TOETVA with drainage.

Materials And Methods: Patients who underwent TOETVA between January 2018 and December 2021 were divided into drainage ( = 20) and Tisseel ( = 30) groups.

View Article and Find Full Text PDF

Hemostatic Efficacy of TachoSil in Loop Electrosurgical Excisional Procedure: A Prospective Randomized Controlled Study.

J Low Genit Tract Dis

January 2025

Department of Obstetrics and Gynecology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea.

Objective: The aim of the study was to evaluate the hemostatic efficacy of the fibrin sealant patch (TachoSil) after loop electrosurgical excision (LEEP) and its influence on other complications and quality of life (QoL).

Materials And Methods: This single-blind, prospective, randomized study involved patients undergoing LEEP with or without TachoSil (1:1) between August 2014 and August 2015 in Asan Medical Center, Korea. Primary outcome measures were bleeding duration and the frequency of additional treatment owing to vaginal bleeding within 2 weeks after LEEP.

View Article and Find Full Text PDF

Burns carry a large surface area, varying in shapes and depths, and an elevated risk of infection. Regardless of the underlying etiology, burns pose significant medical challenges and a high mortality rate. Given the limitations of current therapies, tissue-engineering-based treatments for burns are inevitable.

View Article and Find Full Text PDF

This study is aimed at evaluating the effectiveness of TachoSil in controlling lymphatic leakage in breast cancer patients undergoing axillary dissection. By examining its ability to reduce postsurgical lymphatic drainage, the study will assess its impact on complications like seroma formation, recovery time, and overall patient outcomes, including quality of life and reduced healthcare costs. Breast cancer patients treated in the Department of Surgical Oncology at King Abdulaziz Medical City were enrolled to receive either TachoSil or undergo drain placement after axillary dissection.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!