Time-resolved computed tomography of the liver: retrospective, multi-phase image reconstruction derived from volumetric perfusion imaging.

Eur Radiol

Division of Medical Imaging and Technology, Department of Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institutet, Karolinska University Hospital, 14186, Stockholm, Sweden,

Published: January 2014

Objective: To assess feasibility and image quality (IQ) of a new post-processing algorithm for retrospective extraction of an optimised multi-phase CT (time-resolved CT) of the liver from volumetric perfusion imaging.

Methods: Sixteen patients underwent clinically indicated perfusion CT using 4D spiral mode of dual-source 128-slice CT. Three image sets were reconstructed: motion-corrected and noise-reduced (MCNR) images derived from 4D raw data; maximum and average intensity projections (time MIP/AVG) of the arterial/portal/portal-venous phases and all phases (total MIP/ AVG) derived from retrospective fusion of dedicated MCNR split series. Two readers assessed the IQ, detection rate and evaluation time; one reader assessed image noise and lesion-to-liver contrast.

Results: Time-resolved CT was feasible in all patients. Each post-processing step yielded a significant reduction of image noise and evaluation time, maintaining lesion-to-liver contrast. Time MIPs/AVGs showed the highest overall IQ without relevant motion artefacts and best depiction of arterial and portal/portal-venous phases respectively. Time MIPs demonstrated a significantly higher detection rate for arterialised liver lesions than total MIPs/AVGs and the raw data series.

Conclusion: Time-resolved CT allows data from volumetric perfusion imaging to be condensed into an optimised multi-phase liver CT, yielding a superior IQ and higher detection rate for arterialised liver lesions than the raw data series.

Key Points: • Four-dimensional computed tomography is limited by motion artefacts and poor image quality. • Time-resolved-CT facilitates 4D-CT data visualisation, segmentation and analysis by condensing raw data. • Time-resolved CT demonstrates better image quality than raw data images. • Time-resolved CT improves detection of arterialised liver lesions in cirrhotic patients.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00330-013-2992-xDOI Listing

Publication Analysis

Top Keywords

raw data
20
volumetric perfusion
12
image quality
12
detection rate
12
arterialised liver
12
liver lesions
12
computed tomography
8
perfusion imaging
8
optimised multi-phase
8
evaluation time
8

Similar Publications

Low-carbon fuels, emitting less carbon than fossil fuels, are proposed to help in the transition to a sustainable, decarbonized transport sector. The new biofuels being studied and developed in this context include hydrotreated vegetable oils (HVO). Its chemical composition, which is the same as fossil diesel (primarily composed of linear chain hydrocarbons C12-C24), makes HVO (more homogeneous mixtures of paraffinic hydrocarbons C10-C20, containing no sulfur or aromatics) a fuel with slightly lower density than fossil diesel due to these characteristics.

View Article and Find Full Text PDF

Saline-tolerant medicinal plants possess novel chemical constituents with high bioactivity because of their unique secondary metabolic pathways. an aquatic plant found in the coastal wetlands of the Yellow River Delta, was collected and studied in the present work. Ten drimane-type sesquiterpenoids and four triterpenoids, including six new ones (sinenseines A-F), were isolated from a whole plant of for the first time.

View Article and Find Full Text PDF

Biochemical components of corneal stroma: a study on myopia classification based on Raman spectroscopy and deep learning methods.

Biomed Opt Express

January 2025

Center for Biomedical-photonics and Molecular Imaging, Advanced Diagnostic-Therapy Technology and Equipment Key Laboratory of Higher Education Institutions in Shaanxi Province, School of Life Science and Technology, Xidian University, Xi'an, Shaanxi 710126, China.

The study aimed to identify differences in the biochemical composition of corneal stroma lenses across varying degrees of myopia using Raman spectrum characteristics. Corneal stroma lens samples from 38 patients who underwent small incision lens extraction (SMILE) surgery, were categorized into low (n = 9, spherical power -3.00D), moderate (n = 23, spherical power < -3.

View Article and Find Full Text PDF

Small and medium-scale biorefineries are processing facilities designed to produce a portfolio of value-added products with applications in different productive sectors. The Territory of the Southern Coast (TSC) of Bahia in Brazil has a high potential to provide agricultural and forest biomass for these bioindustries. This study focuses on quantifying the biomass of key agricultural crops in the TSC from 1999 to 2019, utilizing data from the Municipal Agricultural Production (MAP) survey conducted by the Brazilian Institute of Geography and Statistics (IBGE).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!