Transradial access for coronary intervention significantly reduces vascular complications and may be associated with a reduced risk of major adverse cardiovascular events. However, the small caliber of the radial artery has been considered a limitation to performing complex coronary intervention. Fifty-three patients with true bifurcation disease, in whom a two-stent strategy was felt to be indicated, were scheduled to undergo crush stenting via the transradial approach. Procedural outcome was recorded and 6- and 18-month clinical follow-up was performed. Successful crush stenting via the radial artery was performed in 51/55 lesions (93%). Crush stenting was performed in 53 lesions overall and successful final kissing inflation was achieved in 51/53 (96%). There were no in-hospital or procedural complications. The overall rate of death, myocardial infarction, or target vessel revascularization was 9.8% at 18-month follow-up. Complex percutaneous coronary intervention requiring large-bore catheters can be performed successfully in a high proportion of patients via the transradial approach. Crush stenting, with a very high rate of final kissing inflation, was associated in this series with excellent procedural and medium-term outcomes.
Download full-text PDF |
Source |
---|
J Clin Med
January 2025
Cardiology Department, "Victor Babes" University of Medicine and Pharmacy, 2 Eftimie Murgu Sq., 300041 Timisoara, Romania.
True trifurcation disease of the left main coronary artery is a rare situation encountered in clinical practice. To date, there is no evidence for a standardized strategy of percutaneous coronary intervention in this type of lesion. This article describes a novel three-stent strategy using a combination of Triple-Kissing Balloon Crush in both of the side branches.
View Article and Find Full Text PDFCan J Cardiol
January 2025
Istanbul Mehmet Akif Ersoy Thoracic and Cardiovascular Surgery Training and Research Hospital, Department of Cardiology, Istanbul, Türkiye.
Background: This multicenter study aimed to retrospectively evaluate the mid-term clinical outcomes of mini-crush (MCT) and nano-crush (NCT) techniques in patients with complex bifurcation lesions (CBLs).
Methods: The study comprised 431 patients [male: 318 (73.8%), mean age: 60.
J Invasive Cardiol
January 2025
Minneapolis Heart Institute and Minneapolis Heart Institute Foundation, Abbott Northwestern Hospital, Minneapolis, Minnesota. Email:
Background: Upfront 2-stent techniques are often used in bifurcation percutaneous coronary interventions (PCI), but there is controversy about optimal strategy selection.
Methods: The authors examined the clinical and angiographic characteristics and long-term outcomes of 232 bifurcation PCIs that were performed using the double kissing (DK) crush or culotte technique in 216 patients between 2014 and 2023 using data from the Prospective Global Registry for the Study of Bifurcation Lesion Interventions (NCT05100992). The inverse probability of treatment weighted (IPTW) Cox proportional hazards model was used to assess long-term outcomes.
Prog Cardiovasc Dis
December 2024
Division of Cardiovascular Medicine, Department of Medicine, University of Virginia, Charlottesville, VA 22908, United States of America. Electronic address:
Revascularization has been demonstrated to be clearly superior to medical therapy for significant unprotected left main coronary artery (LMCA) disease. Coronary artery bypass graft surgery (CABG) has a class 1 indication in both the American and European society guidelines for the treatment of LMCA disease. However, for the population of patients who are declined CABG after a heart team evaluation, percutaneous coronary interventional (PCI) may be an efficacious alternative.
View Article and Find Full Text PDFBioact Mater
April 2025
University of Coimbra, CEMMPRE, Department of Mechanical Engineering, 3030-788, Coimbra, Portugal.
Polymeric coronary stents, like the ABSORB™, are commonly used to treat atherosclerosis due to their bioresorbable and cell-compatible polymer structure. However, they face challenges such as high strut thickness, high elastic recoil, and lack of radiopacity. This study aims to address these limitations by modifying degradable stents produced by additive manufacturing with poly(lactic acid) (PLA) and poly(ε-caprolactone) (PCL) with degradable metallic coatings, specifically zinc (Zn) and magnesium (Mg), deposited via radiofrequency (rf) magnetron sputtering.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!