In this work, a simple and high sensitivity electrochemical sensor was developed to determine Sudan I based on Pt/CNTs nanocomposite ionic liquid modified carbon paste electrode (Pt/CNTs/ILCPE) using cyclic voltammetry, electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV) methods. The novel sensor exhibited an obviously catalytic activity towards the oxidation of Sudan I, which can be confirmed by the increased oxidation peak current and the decreased oxidation peak potential when compared with the bare carbon paste electrode (CPE). The electron transfer coefficient (α), diffusion coefficient (D), and charge transfer resistance (Rct) of Sudan I at the modified electrode were calculated. The linear response range and detection limit were found to be 0.008-600 μmol L(-1) and 0.003 μmol L(-1), respectively. Other species did not interfere with the determination of Sudan I at a surface of propose sensor in the optimum condition. The proposed sensor was successfully applied for the determination of Sudan I in food samples with satisfactory results.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.foodchem.2013.07.020 | DOI Listing |
Chem Biomed Imaging
December 2024
Department of Chemistry "G.Ciamician", University of Bologna, UE4, Via. P. Gobetti 85, 40129 Bologna, Italy.
Electrochemiluminescence (ECL) is nowadays a powerful technique widely used in biosensing and imaging, offering high sensitivity and specificity for detecting and mapping biomolecules. Screen-printed electrodes (SPEs) offer a versatile and cost-effective platform for ECL applications due to their ease of fabrication, disposability, and suitability for large-scale production. This research introduces a novel method for improving the ECL characteristics of screen-printed carbon electrodes (SPCEs) through the application of CO laser treatment following fabrication.
View Article and Find Full Text PDFTalanta
December 2024
Department of Chemistry, University of Texas at San Antonio, TX, 78249, USA. Electronic address:
Aminated carbon nanotubes, CNT, were covalently modified with glutardialdehyde (GDI) and the redox dye Azure to form a new electrode material CNT-GDI-Azure (CGA). The nanocomposite of CGA and polysaccharide chitosan was used for the anodic determination of NADH. Compared to conventional carbon and metal electrodes, the CGA electrode drastically lowered the overpotential for NADH oxidation (by > 0.
View Article and Find Full Text PDFSci Rep
December 2024
Department of Civil, Environmental and Mechanical Engineering, University of Trento, Via Mesiano, 77, 38123, Trento, Italy.
In this study, DL-phenylalanine modified with a multiwall carbon nanotube paste electrode is used as advanced electrochemical sensor for analysing of 0.1 mM caffeic acid (CFA) with simultaneous detection of riboflavin (RFN). The developed sensors include electrochemically polymerized DL-phenylalanine (DL-PA) modified multiwall carbon nanotube paste electrode [DL-PAMMCNTPE] and bare multiwall carbon nanotube paste electrode [BMCNTPE].
View Article and Find Full Text PDFJ Funct Biomater
December 2024
Department of Veterinary Anatomy, Histology and Embryology, Faculty of Veterinary Medicine, Trakia University, 6000 Stara Zagora, Bulgaria.
Background: Supragingival polishing is a crucial part of nonsurgical periodontal therapy. In recent years, air polishing has been used for this purpose, introducing different polishing powders. The purpose of the following study was to investigate the damage to the gingival margin during air polishing by an inexperienced operator.
View Article and Find Full Text PDFAngew Chem Int Ed Engl
December 2024
Shanghai Institute of Technology, School of Chemical and Environmental Engineering, CHINA.
Laminating a free-standing carbon electrode film onto perovskite film is a promising method for fabricating HTM (hole transport material)-free carbon electrode perovskite solar cells (c-PSCs), offering more flexibility by decoupling the processes of carbon electrode and perovskite layer formation. However, the power conversion efficiency (PCE) of laminated HTM-free c-PSCs (<16.5%) remains lower compared to c-PSCs with printed carbon pastes (>20%), primarily due to poor interfacial contact between the perovskite and carbon layers.