A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Amperometric biosensor for the determination of histamine in fish samples. | LitMetric

Amperometric biosensor for the determination of histamine in fish samples.

Food Chem

Sensors and Biosensors Group, Department of Chemistry, Universitat Autònoma de Barcelona, Edifici Cn, 08193 Bellaterra, Barcelona, Spain.

Published: December 2013

A bienzymatic biosensor employing diamine oxidase (DOx) and horseradish peroxidase (HRP) for the detection of histamine in fish samples has been developed and optimized in this work. These enzymes have been co-immobilized into a polysulfone/carbon nanotubes/ferrocene membrane by means of phase inversion technique onto screen-printed electrodes. The electrochemical measurements have been carried out in phosphate buffer solution at pH 8.0 in batch mode and low applied potential (-50 mV vs. Ag/AgCl, KCl 0.1 M) to minimize the interferences. Developed biosensor exhibits high sensitivity (1.9×10(7) nA(-1)), low limit of detection (1.7×10(-7) M), high storage stability and excellent reproducibility, obtaining a linear interval range from 3×10(-7) to 2×10(-5) M. Finally, applicability of the biosensor to the estimation of histamine content in different fish samples has been assessed; obtaining a good correlation between results obtained with the biosensor and those obtained with the reference method (ELISA) in case of sardines, mackerel and greater weever.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.foodchem.2013.06.125DOI Listing

Publication Analysis

Top Keywords

fish samples
12
histamine fish
8
amperometric biosensor
4
biosensor determination
4
determination histamine
4
samples bienzymatic
4
biosensor
4
bienzymatic biosensor
4
biosensor employing
4
employing diamine
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!