Our goal was to report a 10-year follow up of linear penetration rates for HCLPE, and to determine whether a difference exists between penetrations measured on pelvis or hip anterior-posterior radiographs. We reviewed 48 total hip arthroplasties where a first-generation HCLPE liner was used. Femoral head penetration was measured on both AP pelvis and hip radiographs. Total wear and wear rate at 10 years were 1.26 mm and 0.122 mm/y, respectively. The rate decreased significantly after the first 2-3 years, plateauing at a wear rate of 0.05 mm/y for the last 5 years. The AP hip total wear and wear rate were 1.38 mm and 0.133 mm/y respectively, while rates were 1.13 mm and 0.109 mm/y respectively for the pelvis radiographs (P<.05). We found a significant difference in measurements of linear penetration when comparing AP pelvis vs. hip radiographs with lower rates recorded using an AP pelvis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2013.07.034DOI Listing

Publication Analysis

Top Keywords

wear rate
12
total hip
8
measured pelvis
8
pelvis hip
8
total wear
8
wear wear
8
wear
6
hip
5
10-year follow-up
4
follow-up wear
4

Similar Publications

Introduction: Opioid overdose and blood-borne virus transmission are key health risks for people who inject drugs. Existing study methods that record data on injecting drug risks mostly rely on retrospective self-reporting that, while valid, are limited to being broad and subject to recall bias. The In-The-Moment-Expanded (ITM-Ex) study will evaluate the feasibility and acceptability of multiple novel data collection methods to capture in situ drug injecting data.

View Article and Find Full Text PDF

Aims: The aim of this study was to report long-term clinical outcomes of a modern convertible metal-backed glenoid (MBG) in total shoulder arthroplasty (TSA).

Methods: After a minimum of 15 years, a previously studied cohort of 35 patients who received a modern convertible MBG during the period 1996 to 2005 was contacted for clinical and radiological follow-up. At last follow-up, patients were evaluated radiologically and clinically according to the Constant Score, Simple Shoulder Test, and visual analogue scale for pain.

View Article and Find Full Text PDF

Background: Ambient air pollution, detrimental built and social environments, social isolation (SI), low socioeconomic status (SES), and rural (versus urban) residence have been associated with cognitive decline and risk of Alzheimer's disease and related dementias (ADRD). Research is needed to investigate the influence of ambient air pollution and built and social environments on SI and cognitive decline among rural, disadvantaged, ethnic minority communities. To address this gap, this cohort study will recruit an ethnoracially diverse, rural Florida sample in geographic proximity to seasonal agricultural burning.

View Article and Find Full Text PDF

Optimal submicron roughness for balancing degradation behavior, immune modulation, and microbial adhesion on zinc-based barrier membranes.

Biomater Adv

December 2024

Department of Prosthodontics, School and Hospital of Stomatology, Guangdong Engineering Research Center of Oral Restoration and Reconstruction, Guangzhou Medical University, Guangzhou 510180, China; Guangzhou Key Laboratory of Basic and Applied Research of Oral Regenerative Medicine, Guangzhou Medical University, Guangzhou 510180, China. Electronic address:

Metallic zinc (Zn) has been demonstrated to be a promising alternative to barrier membrane materials for guided bone regeneration. Surface roughness significantly affects the properties of degradable Zn-based metals, especially within the Janus micro-environments of tissue regeneration. However, the effects of optimal surface roughness on Zn remain unknown.

View Article and Find Full Text PDF

The abrasive wear performance of TiC particle-reinforced high-manganese steel matrix composites with a spherical hierarchical structure under moderate impact energy was investigated. In the composites, TiC particles (10 μm in diameter) were concentrated within discrete spherical composite regions with diameters of about 100 μm. Impact abrasive wear tests were conducted to evaluate the wear performance of the composites with different volume fractions (30%, 40%, and 50%) of TiC particles compared with the matrix and a uniformly distributed TiC particle composite.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!