A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Impact of tunnels and tenodesis screws on clavicle fracture: a biomechanical study of varying coracoclavicular ligament reconstruction techniques. | LitMetric

Purpose: The purpose of this study was to compare the load to fracture of distal clavicles with no tunnels, one tunnel, or 2 tunnels and to evaluate the effect of inserting tenodesis screws in the tunnels on load to fracture of the distal clavicle.

Methods: Fifty right sawbone clavicles were obtained and divided into 5 groups (n = 10): group 1, normal clavicle; group 2, one tunnel, no tenodesis screw; group 3, 2 tunnels, no tenodesis screws; group 4, one tunnel with tenodesis screw; and group 5, 2 tunnels with 2 tenodesis screws. Tunnels were created using a 5-mm-diameter reamer, and 5.5 × 10 mm polyethyl ethyl ketone tenodesis screws were used. A 4-point bending load was applied to the distal clavicles. Load to failure was noted for each specimen.

Results: Load to failure in clavicles without tunnels was significantly higher (1,157.18 ± 147.10 N) than in all other groups (P < .0005). No statistical differences were noted between groups 2, 3, 4, and 5. Load to failure was not statistically different in clavicles with one versus 2 tunnels. In addition, the use of tenodesis screws in the tunnels did not affect the load required to fracture.

Conclusions: The use of tunnels in the clavicle for coracoclavicular (CC) ligament reconstruction significantly reduces the load required to fracture the distal clavicle. The addition of tenodesis screws does not appear to significantly increase the strength of the clavicle in this construct.

Clinical Relevance: CC ligament reconstruction techniques commonly use tunnels in the distal clavicle, which may render the clavicle more susceptible to fracture. This study helps quantify the effect of these tunnels on the strength of the distal clavicle.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arthro.2013.07.257DOI Listing

Publication Analysis

Top Keywords

tenodesis screws
28
tunnels tenodesis
12
ligament reconstruction
12
fracture distal
12
tunnels
12
screws tunnels
12
load failure
12
distal clavicle
12
tenodesis
9
clavicle
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!