Endotracheal intubation has been associated with a threefold higher incidence of laryngopharyngeal complaints following anesthesia in comparison to laryngeal mask airway. Such complaints, including hoarseness and sore throat, have been reported in up to 90% of patients within 24 h of extubation. The purpose of this study was to determine which preoperatively documented clinical and anatomic parameters are predictive of laryngo-pharyngeal trauma resulting from elective endotracheal intubation. Fifty-three patients undergoing ENT procedures requiring general anesthesia with endotracheal intubation were recruited. Pre and postoperative laryngostroboscopic examination was performed and findings correlated to preoperative clinical and anatomic parameters. Readily assessed anatomic parameters including height (>180 cm) and weight (>80 kg) correlated significantly to the Eckerbom grade of intubation-associated acute laryngeal injury (rs = 0.374; p = 0.006 and rs = 0.278; p = 0.044, respectively). The mandibular protrusion test also correlated significantly to the Eckerbom grade (rs = 0.462, p = 0.001) while the upper-lip-bite test showed significant correlation to impaired vocal fold oscillation (rs = 0.288, p = 0.036), with injury prediction sensitivities of 37.5 and 39.4%, respectively. No parameters correlated to subjective complaints (n = 5, 9.2%). This study provides suggestions on how to improve the classification of intubation-associated laryngeal injuries as well as providing the basis for larger clinical trials in other surgical subspecialties.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00405-013-2659-x | DOI Listing |
BMC Pulm Med
December 2024
Department of Neonatology, Children's Hospital of Chongqing Medical University, Chongqing, 400,014, China.
Purpose: To compare five pulmonary surfactant (PS) administration strategies for neonates with respiratory distress syndrome (RDS), including intubation-surfactant-extubation (InSurE), thin catheter administration, laryngeal mask airway (LMA), surfactant nebulization (SN), and usual care, with a particular emphasis on the comparison of the LMA and SN with other strategies.
Methods: We conducted a systematic search of MEDLINE, EMBASE, PUBMED, and Cochrane CENTRAL databases up to November 2023. Two authors independently conducted data extraction, and assessed bias using the Cochrane Risk of Bias Tool.
J West Afr Coll Surg
August 2024
Department of Anaesthesia, University of Nigeria Teaching Hospital, Ituku-Ozalla, Enugu, Nigeria.
Background: Considerable morbidity is attributable to inappropriate tracheal cuff pressure. An earlier study undertaken in our hospital revealed that a normal cuff pressure of 20-30 cm HO was achieved in only 6% of intubated patients using subjective estimation methods.
Objective: To determine whether a training intervention could improve the accuracy of the subjective estimation method in our tracheal cuff monitoring.
Pediatr Qual Saf
December 2024
From the Division of Neonatology, Department of Pediatrics, St. Christopher's Hospital for Children, Philadelphia, Pa.
Introduction: Although associated with respiratory morbidity, elective endotracheal intubation (ETI) for laser photocoagulation for retinopathy of prematurity (ROP) is the standard practice at our institution, with 100% of patients undergoing preoperation ETI. To mitigate this risk, we strove to reduce the percentage of infants intubated for laser photocoagulation by 30% by June 2022.
Methods: We assembled a multidisciplinary team and implemented a deep sedation guideline utilizing dexmedetomidine, fentanyl, and midazolam with noninvasive ventilation support for laser photocoagulation in January 2020.
Pediatr Qual Saf
December 2024
Division of Neonatology, Department of Pediatrics, Hackensack-Meridian Health, Hackensack University Medical Center, Hackensack, N.J.
Introduction: Endotracheal intubation is frequent in the neonatal intensive care unit (NICU) but may result in neonatal distress and instability. Premedication reduces adverse effects, such as hypoxia, bradycardia, and pain. The Specific, Measurable, Achievable, Relevant and Time-Bound aim for this project was to increase premedication use for nonemergent neonatal intubation in a specific NICU from 22% to 80% from March 2021 to May 2023.
View Article and Find Full Text PDFAdv Med Educ Pract
December 2024
Department of Anesthesiology and Intensive Therapy, Medical University of Lodz, Lodz, Poland.
Background: Videolaryngoscopes increased the safety of patients requiring endotracheal intubation. Their particular beneficiaries are healthcare providers inexperienced in intubation. We compared the learning curve of McGrath, UESCOPE, and Airtraq VLs among the first-year anesthesiology residents.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!