A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Femtosecond digital lensless holographic microscopy to image biological samples. | LitMetric

AI Article Synopsis

  • The study explores using femtosecond laser radiation in digital lensless holographic microscopy (DLHM) to image biological samples.
  • A Ti:Sa laser emitting ultrashort 12 fs pulses at 800 nm wavelength was used, alongside a light-emitting diode for comparison.
  • Findings reveal significant differences in how pinhole size affects spatial resolution in DLHM when using different light sources, uncovering previously unrecognized phenomena in the field.

Article Abstract

The use of femtosecond laser radiation in digital lensless holographic microscopy (DLHM) to image biological samples is presented. A mode-locked Ti:Sa laser that emits ultrashort pulses of 12 fs intensity FWHM, with 800 nm mean wavelength, at 75 MHz repetition rate is used as a light source. For comparison purposes, the light from a light-emitting diode is also used. A section of the head of a drosophila melanogaster fly is studied with both light sources. The experimental results show very different effects of the pinhole size on the spatial resolution with DLHM. Unaware phenomena on the field of the DLHM are analyzed.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.38.003205DOI Listing

Publication Analysis

Top Keywords

digital lensless
8
lensless holographic
8
holographic microscopy
8
image biological
8
biological samples
8
femtosecond digital
4
microscopy image
4
samples femtosecond
4
femtosecond laser
4
laser radiation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!