A generic three-dimensional static force distribution basis for a medical needle inserted into soft tissue.

J Mech Behav Biomed Mater

UJF-Grenoble1, CNRS, TIMC-IMAG UMR5525, Grenoble, France. Electronic address:

Published: December 2013

In this paper, the static interaction forces between a medical needle and soft tissue during CT (Computerized Tomography) guided insertion are studied. More precisely a set of linearly independent elements describing the forces (a basis) is identified. This forms a generic basis from which any forces that act on a static needle (that is not fixed at its base and that is inserted into human tissue) can be described accurately. To achieve this purpose, the same needle was inserted 62 times into fresh porcine shoulder tissue and CT scans were acquired after each push to determine the final trajectory of the needle. From this set of trajectories, a generic static force basis was determined by using static Beam, B-spline theories and Principal Component Analysis (PCA). This generic basis was first validated on theoretical simulations and then on 20 different needles inserted into in vivo human tissues during real clinical interventions. Such a basis could be of use to highlight the forces acting all along the length of a needle inserted into a complex tissue and enables models of needle deflection to be developed. These models could be used in the development of automated robot assisted and/or image guided strategies for needle steering.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmbbm.2013.07.023DOI Listing

Publication Analysis

Top Keywords

needle inserted
12
static force
8
needle
8
medical needle
8
soft tissue
8
generic basis
8
basis
6
static
5
inserted
5
tissue
5

Similar Publications

Purpose: The multi-modality imaging system offers optimal fused images for safe and precise interventions in modern clinical practices, such as computed tomography-ultrasound (CT-US) guidance for needle insertion. However, the limited dexterity and mobility of current imaging devices hinder their integration into standardized workflows and the advancement toward fully autonomous intervention systems. In this paper, we present a novel clinical setup where robotic cone beam computed tomography (CBCT) and robotic US are pre-calibrated and dynamically co-registered, enabling new clinical applications.

View Article and Find Full Text PDF

Objective: To investigate the clinical efficacy of a method that corrects tear trough deformity by subcutaneous fixation of orbital septal fat flaps using syringe-guided absorbable barbed sutures.

Methods: A retrospective analysis was conducted on the clinical data of 125 cases with lower eyelid bags accompanied by tear trough deformity who were treated in the Department of Plastic Surgery at Zhengzhou People's Hospital from 2020 to 2024. Among them, there were 13 males and 112 females, with an average age of 34.

View Article and Find Full Text PDF

Introduction: Despite the growing clinical use of dry needling (DN) among physical therapists in the United States and its gradual adoption into entry-level Doctor of Physical Therapy (DPT) programs, limited research exists on DN safety within educational settings. This study aims to report the type and incidence of adverse events (AEs) associated with DN instruction in DPT programs.

Review Of Literature: To date, there has been no reporting on DN-related AEs during DPT education, making the relative risk of DN education unclear.

View Article and Find Full Text PDF

Purpose: This study aims to describe an innovative suprachoroidal space injection technique using a combination of 30 G and 22 G needles attached to a 1 ml injector. The efficacy and applicability of this technique in suprachoroidal injections are evaluated.

Methods: In this study, we conducted both and injection experiments using isolated porcine eyes and live SD rats, respectively.

View Article and Find Full Text PDF

Background: Centrally inserted central catheterization (CICC) is a critical procedure in pediatric care. However, CICC in children poses greater challenges compared to adults due to anatomical and physiological differences, leading to higher complication rates. Ultrasound-guided approaches have been developed to enhance the safety and effectiveness of CICC, but the comparative efficacy of different axis approaches remains unclear.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!