A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A validated stability-indicating TLC-densitometric method for the determination of stanozolol in pharmaceutical formulations. | LitMetric

A validated stability-indicating TLC-densitometric method for the determination of stanozolol in pharmaceutical formulations.

Chem Cent J

H,E,J, Research Institute of Chemistry, International Center for Chemical and Biological Sciences, University of Karachi, Karachi 75270, Pakistan.

Published: August 2013

Background: Stanozolol is a synthetic derivative of dihydrotestosterone (DHT), and one of the frequently detected anabolic steroids in doping analysis. The current work describes the development and validation of the stability-indicating TLC-densitometric method for sensitive and specific estimation of stanozolol even its degradation product being there. Precoated silica gel TLC aluminium plates were utilized as the stationary phase and the eluent comprised of petroleum ether: acetone (6:4, v/v). Densitometric analysis of stanozolol was achieved at λmax 750 nm in the absorbance mode after staining with phosphomolybdic acid (PMA). Stress degradation of stanozolol was carried out under various reaction conditions including acid, base and neutral hydrolysis, wet and dry heating treatment, oxidation, and photo-degradation. Resulted stress samples and pharmaceutical products were analyzed with the developed TLC method.

Results: This system showed a compact spot for stanozolol at Rf value of 0.46 ± 0.02. The data of linear regression analysis indicated a good linear relationship over the range of 200-1200 ng/spot concentrations. The method was validated for robustness, precision and recovery. The LOD and LOQ were 1.6 and 5.1 ng/spot, respectively. Under various stressed conditions, stanozolol showed degradation only under acidic hydrolysis. Peak of a degraded product was well resolved from the stanazolol with reasonably different Rf value and identified as 17, 17-dimethyl-l8-nor-5α-androst-13(14)-eno [3,2c] pyrazole through 1D- and 2D-NMR spectroscopic techniques and ESI-QqTOF-MS/MS analysis.

Conclusion: Result reflected that the stanozolol is majorly affected by the acidic condition. Statistical analysis indicated the application of the developed stability-indicating TLC-densitometric method for routine analysis of stanozolol in the presence of its degradation product.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3766227PMC
http://dx.doi.org/10.1186/1752-153X-7-142DOI Listing

Publication Analysis

Top Keywords

stability-indicating tlc-densitometric
12
tlc-densitometric method
12
stanozolol
9
stanozolol degradation
8
degradation product
8
analysis stanozolol
8
analysis indicated
8
analysis
5
validated stability-indicating
4
method
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!