A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Titration of free hydroxyl and strained siloxane sites on silicon dioxide with fluorescent probes. | LitMetric

Titration of free hydroxyl and strained siloxane sites on silicon dioxide with fluorescent probes.

Langmuir

Department of Chemical Engineering, The University of Texas at Austin, Austin, Texas 78712, United States.

Published: September 2013

A technique enabling the detection and quantification of low density sites on planar SiO2 surfaces is demonstrated. Fluorescent probes are used to titrate free hydroxyl and strained siloxane sites on the surface of amorphous SiO2 substrates in vacuum. The titration of free hydroxyl sites was performed to validate the method and to provide a reference for the measurement of the strained siloxane site density. Perylene derivatives with different functional groups are chemisorbed onto the surface sites, enabling in situ photoluminescence (PL) measurements of the bound fluorophores. An amine functional group is used to selectively titrate strained siloxane sites, while an alcohol group is used for the titration of free hydroxyl sites. Emission intensity was found to be nonlinear with coverage for bound fluorophore densities greater than 0.1 nm(-2), necessitating the removal of molecules from the surface into a solution to obtain accurate density measurements. For lower densities, the coverage of bound fluorophores can be estimated directly from in situ PL measurements. The measured areal densities of bound fluorophores after titrating free hydroxyl sites are in good agreement with literature values for the densities of such sites on high surface area silica. PL measurements of SiO2 surfaces titrated with an amine derivative of perylene indicate that strained siloxane sites exist for vacuum pretreatment temperatures of 300 °C and increase with increasing pretreatment temperature. Densities of strained siloxane sites on the silica surface are estimated at 0.004-0.02 nm(-2) for pretreatment temperatures of 300-700 °C, demonstrating the sensitivity of this technique.

Download full-text PDF

Source
http://dx.doi.org/10.1021/la402825tDOI Listing

Publication Analysis

Top Keywords

strained siloxane
24
free hydroxyl
20
siloxane sites
20
titration free
12
hydroxyl sites
12
bound fluorophores
12
sites
11
hydroxyl strained
8
fluorescent probes
8
sio2 surfaces
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!