Background: Current National Comprehensive Cancer Network guidelines recommend repeat imaging 6-12 months after a benign radiologic-pathologic concordant image-guided breast biopsy. We hypothesized that interval imaging <12 months after benign concordant biopsy has a low cancer yield and increases health care costs.

Methods: An institutional review board-approved retrospective chart review identified 689 patients who underwent image-guided breast biopsy at Bryn Mawr Hospital between January and December 2010. Charts were evaluated for documentation of radiologic-pathologic concordance.

Results: Of 689 patients, 188 (27 %) had malignant pathology, 3 (0.4 %) had nonbreast pathology, and 498 (72.3 %) had benign pathology. Of 498 patients with benign findings, 44 (8.8 %) underwent surgical excision as a result of discordance, atypia, papillary lesion, or other benign finding. Of the remaining 454 patients who did not undergo excision, 337 (74.2 %) had documented radiologic-pathologic concordance. Interval imaging <12 months after benign biopsy was obtained in 182 (54.0 %) concordant patients. Five (2.7 %) patients had suspicious [American College of Radiology Breast Imaging-Reporting and Data System (BI-RADS) 4] findings on follow-up imaging. Only one breast cancer was identified, representing 0.5 % (95 % confidence interval 0-3.4) of all benign concordant patients undergoing interval imaging. The cost of detecting a missed cancer with interval imaging after benign concordant biopsy was $41,813.77 in this cohort.

Conclusions: Interval imaging performed <12 months after benign concordant breast biopsy demonstrated a low yield for the detection of breast cancer and resulted in increased health care costs. Our data support the policy for discontinuation of routine interval imaging after benign concordant biopsy.

Download full-text PDF

Source
http://dx.doi.org/10.1245/s10434-013-3114-3DOI Listing

Publication Analysis

Top Keywords

interval imaging
8
benign radiologic-pathologic
8
radiologic-pathologic concordant
8
breast biopsy
8
6-month interval
4
imaging benign
4
concordant minimally
4
minimally invasive
4
invasive breast
4
biopsy background
4

Similar Publications

Background: Computed tomography (CT)-derived low muscle mass is associated with adverse outcomes in critically ill patients. Muscle ultrasound is a promising strategy for quantitating muscle mass. We evaluated the association between baseline ultrasound rectus femoris cross-sectional area (RF-CSA) and intensive care unit (ICU) mortality.

View Article and Find Full Text PDF

Background: Effective pain recognition and treatment in perioperative environments reduce length of stay and decrease risk of delirium and chronic pain. We sought to develop and validate preliminary computer vision-based approaches for nociception detection in hospitalized patients.

Methods: Prospective observational cohort study using red-green-blue camera detection of perioperative patients.

View Article and Find Full Text PDF

Background And Aims: Current heart failure (HF) risk stratification strategies require comprehensive clinical evaluation. In this study, artificial intelligence (AI) applied to electrocardiogram (ECG) images was examined as a strategy to predict HF risk.

Methods: Across multinational cohorts in the Yale New Haven Health System (YNHHS), UK Biobank (UKB), and Brazilian Longitudinal Study of Adult Health (ELSA-Brasil), individuals without baseline HF were followed for the first HF hospitalization.

View Article and Find Full Text PDF

Background And Purpose: While the pulsatility index (PI) measured by transcranial Doppler (TCD) has broader associations with outcomes in neurocritical care, its use in monitoring delayed cerebral infarction (DCI) in patients with aneurysmal subarachnoid hemorrhage (SAH) is not endorsed by current clinical guidelines. Recognizing that arterial pressure gradient (ΔP) can be estimated using PI, we investigated the potential significance of TCD-estimated ΔP.

Methods: In this observational study of 186 SAH patients, we recorded the mean cerebral blood flow velocity (mCBFV) and PI values from the middle cerebral artery, along with corresponding blood pressures.

View Article and Find Full Text PDF

Background And Aims: Many vaping products feature bright colors and novel brand names and flavor descriptors, which may appeal to youth. We measured the strength of the associations between e-liquid packaging design (branded, white standardized or white standardized limiting brand and flavor descriptors) and perceived peer interest in trying the e-liquids among youth.

Design: A between-subjects online experiment.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!