Purpose: To compare the refractive and topographic changes at 1 year in eyes with early and advanced keratoconus undergoing corneal collagen crosslinking (CXL). A prospective, nonrandomized comparative clinical intervention study.

Methods: Thirty eyes of patients with keratoconus underwent CXL. They were divided into 2 groups based on their mean central keratometry: group A [mean central K ≤ 53 diopters (D)] and group B (mean central K > 53 D). Uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), refraction, topography, pachymetry, and endothelial cell counts were evaluated at baseline and at 1, 3, 6, and 12 months of follow-up.

Results: The mean baseline logarithm of the minimum angle of resolution (logMAR) UCVA and logMAR BCVA in group A was 1.007 ± 0.30 and 0.566 ± 0.21, respectively. The values improved to 0.727 ± 0.29 (P = 0.001) and 0.306 ± 0.15 (P = 0.001) at 1-year post CXL. The mean baseline logMAR UCVA and logMAR BCVA in group B were 1.040 ± 0.24 and 0.641 ± 0.25, respectively. It changed to 0.953 ± 0.26 (P = 0.054) and 0.633 ± 0.27 (P = 0.891) at 1 year. The improvement in the UCVA and BCVA was statistically significant in group A as compared with that in group B. The mean baseline flattest, steepest, central, and apical keratometry in group A were 48.7 ± 2.5 D, 54.9 ± 3.3 D, 49.5 ± 1.4 D, and 57.3 ± 2.3 D, respectively. At 12 months, the values changed to 47.8 ± 2.4 D, 54.1 ± 3.0 D, 48.8 ± 1.8 D, and 56.2 ± 2.7 D, the change being statistically significant for mean flat and apical K only (P < 0.05). All the 4 indices did not show any statistically significant difference at 12 months in group B (P > 0.05).

Conclusions: Corneal CXL is more effective in improving the refractive and topographical parameters at 1 year when it is performed early in the course of the disease.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ICO.0b013e3182a02ddbDOI Listing

Publication Analysis

Top Keywords

refractive topographic
8
topographic changes
8
early advanced
8
undergoing corneal
8
corneal collagen
8
collagen crosslinking
8
group
8
keratometry group
8
visual acuity
8
logmar ucva
8

Similar Publications

Changes in the effective optical zone following hyperopic keratorefractive lenticule extraction.

Ann Med

December 2025

Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.

Objective: To evaluate the longitudinal changes in the effective optical zone (EOZ) following hyperopic keratorefractive lenticule extraction (KLEx) and investigate factors influencing the EOZ.

Patients And Methods: This retrospective study included 27 patients who underwent hyperopic KLEx. According to the transition zone (TZ) sizes, they were divided into two groups: group A (21 eyes) with a 2.

View Article and Find Full Text PDF

Comprehensive characterization of tobacco-induced changes in enamel surface topography.

J Oral Biol Craniofac Res

December 2024

Department of Oral Biology and Oral Pathology, Saveetha Dental College and Hopsitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, 600077, India.

Introduction: Enamel translucency, essential for the aesthetic appeal of teeth, is primarily determined by its thickness, quality, and refractive index. Several factors, including age, genetics, diet, oral hygiene practices, fluoride exposure, and acidic challenges, can influence enamel translucency. Tobacco use, in particular, leads to significant alterations in enamel appearance by penetrating its micropores, causing yellowing and browning.

View Article and Find Full Text PDF

Introduction: Implantable collamer lens (ICL) is a posterior chamber phakic intraocular lens. It is usually indicated for high refractive error correction that cannot be treated by laser vision correction due to physical limitations.

Case Presentation: 39 years old male with a past ocular history of keratoconus underwent astigmatic keratotomy followed by crosslinking in both eyes a couple of years later due to signs of corneal ectasia progression.

View Article and Find Full Text PDF

Compartmental analysis of retinal vascular parameters and thickness in myopic eyes using SS-OCTA.

Front Med (Lausanne)

December 2024

Chongqing Key Laboratory of Prevention and Treatment on Major Blinding Diseases, Chongqing Eye Institute, Chongqing Branch (Municipality Division) of National Clinical Research Center for Ocular Diseases, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.

Article Synopsis
  • The study examined how myopia affects the thickness and structure of retinal blood vessels using advanced imaging technology in 100 participants.
  • The findings revealed that individuals with high myopia had significantly lower vessel density and thinner retinal layers, particularly noticeable in the superficial and nerve fiber layers.
  • There was a noted correlation between certain ocular parameters, such as axial length to curvature radius ratio, and retinal thickness in non-high myopic eyes, while high myopic eyes showed less correlation in these aspects.
View Article and Find Full Text PDF

Corneal astigmatism after temporary discontinuation from long-term spherical and toric orthokeratology.

Cont Lens Anterior Eye

January 2025

Laboratory of Optometry and Vision Sciences, West China School of Medicine, Sichuan University, Chengdu, China; Department of Optometry and Vision Sciences, West China School of Medicine, Sichuan University, Chengdu, China.

Objective: To investigate changes in corneal astigmatism (curvatures and corneal sagittal height difference (C-sagDiff) at 8-mm chord) after temporary discontinuation from long-term spherical and toric orthokeratology (ortho-k) lens wear in a Chinese population.

Methods: Relevant data were retrieved from 110 patients (55 wearing spherical ortho-k lenses, 55 wearing toric ortho-k lenses) who have been undergoing ortho-k treatment for at least one year and stopped lens wear temporarily for scheduled lens replacement. The topographic and refraction data at baseline and post-discontinuation was collected for all the patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!