Introduction: Myocardial perfusion scintigraphy (MPS) is an established non-invasive technique for the diagnosis and management of patients with suspected or known coronary artery disease. Because of the wealth of prognostic data, MPS single photon emission computed tomography (SPECT) is the most commonly used functional test to detect inducible ischaemia. However, the increasing availability of positron emission tomography (PET) scanners for oncology along with the introduction of the generator-produced PET tracer rubidium-82 (⁸²Rb) has helped the growth of MPS PET.
Sources Of Data: Relevant review articles, primary literature and clinical guidelines identified through medical literature search engines.
Areas Of Agreement: PET offers advantages over SPECT, including increased patient throughput because of rapid scanning protocols, reduced radiation exposure to patients and the ability to quantify tracer distribution accurately and hence measure myocardial perfusion in millilitre per gram per minute and hence myocardial perfusion reserve (MPR).
Areas Of Controversy: Although PET has advantages over SPECT, there are no large-scale prognostic or cost-effectiveness data to support it use as the primary MPS technique.
Growing Points: A wider use of absolute measurements of perfusion has the potential to improve diagnostic accuracy and to add prognostic value over relative assessment of myocardial perfusion.
Areas Timely For Developing Research: Assessment of absolute myocardial perfusion may provide insight into the effects of traditional risk factors on perfusion reserve and the impact of risk factor modifications on progression of coronary artery disease.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/bmb/ldt026 | DOI Listing |
Sci Rep
December 2024
Department of Cardiac Surgery, Boston Children's Hospital, 300 Longwood Ave, Boston, MA, 02115, USA.
Heart transplantation remains the ultimate treatment strategy for neonates and children with medically refractory end-stage heart failure and utilization of donors after circulatory death (DCD) can expand th donor pool. We have previously shown that mitochondrial transplantation preserves myocardial function and viability in neonatal swine DCD hearts to levels similar to that observed in donation after brain death (DBD). Herein, we sought to investigate the transcriptomic and proteomic pathways implicated in these phenotypic changes using ex situ perfused swine hearts.
View Article and Find Full Text PDFInt Immunopharmacol
December 2024
Department of Critical Care Medicine, the First Affiliated Hospital of Jinan University, Guangzhou 510632, Guangdong, China. Electronic address:
Previous studies demonstrated that dexmedetomidine (Dex) posttreatment aggravated myocardial dysfunction and reduced survival in septic mice. Yet, whether Dex elicits similar effects in septic patients as defined by Sepsis-3 remains unknown. This study sought to assess the effects of Dex-based sedation on mortality and cardiac dysfunction in septic patients defined by Sepsis-3 and to further reveal the mechanisms in septic rats.
View Article and Find Full Text PDFJ Biomed Phys Eng
December 2024
Department of Medical Physics and Engineering, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran.
Background: Coronary heart disease the most prevalent form of cardiovascular disease, results from the blockage of blood flow through arteries. The Myocardial Perfusion Scan (MPS) is considered a non-invasive method to assess the heart condition and provides valuable information, such as End Diastolic Volume (EDV), End Systolic Volume (ESV), Ejection Fraction (EF), Lung to Heart Ratio (LHR), and Transient Ischemic Dilatation (TID).
Objective: This study aimed to investigate changes in gated heart scan parameters to diagnose patients, who are candidates for heart surgery.
Eur Heart J Imaging Methods Pract
July 2024
Department of Cardiovascular Sciences, University of Leicester and the National Institute for Health Research Leicester Biomedical Research Centre, Glenfield Hospital, Leicester LE3 9QP, UK.
Aims: Patients with atrial fibrillation (AF) are thought to have an attenuated response to adenosine during vasodilator stress testing. We sought to investigate the haemodynamic and hyperaemic effects of adenosine in patients with AF undergoing adenosine-stress cardiovascular magnetic resonance (CMR) assessment.
Methods And Results: We retrospectively examined 318 patients referred for clinical adenosine-stress CMR (AF = 158, sinus rhythm [SR] = 160).
Perfusion
December 2024
Department of Advanced Spectroscopy and Imaging, Centre of Biomedical Research, Lucknow, India and Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, India.
Introduction: Cardioplegia (CP) is integral to myocardial protection during cardiac surgery. Two standard cardioplegic solutions viz. Del Nido solution (DNS) and St Thomas solution (STS) are widely used in cardiac surgeries.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!