Purpose: To determine the feasibility and accuracy of real time 3D echocardiography (RT3DE) in determining the dimensions and anatomical type of the patent ductus arteriosus (PDA).

Methods: The study included 42 pediatric patients with a mean age of 3.6 years (ranging from 2 months to 14 years) who were referred for elective percutaneous PDA closure. All patients underwent full 2D echocardiogram as well as RT3DE with off line analysis using Q lab software within 6 h from their angiograms. The PDA was studied as regard the anatomical type, length of the duct as well as the ampulla and the pulmonary end of the PDA. Data obtained by RT3DE was compared against 2D echocardiogram and the gold standard angiography.

Results: Offline analysis of the PDA was feasible in 97.6% of the cases while determination of the anatomical type using gated color flow 3D acquisitions was achieved in 78.5% of the cases. The pulmonary end of the duct was rather elliptical using 3D echocardiogram. There was significant difference between the pulmonary end measured by 3D echocardiogram and angiography (P < 0.001). There was no significant difference between either the length or the ampulla of the PDA measured by 3D echocardiogram and that measured by angiography (P value = 0.325 and 0.611, respectively). There was a good agreement between both 2D or 3D echocardiogram and angiography in determining the anatomical type of the PDA (K = 0.744 and 0.773, respectively). However 3D echocardiogram could more accurately determine type A and type E ductus compared to 2D echocardiogram.

Conclusion: 3D echocardiogram was more accurate than 2D echocardiogram in determining the length and the ampulla of the PDA. The morphologic assessment of the PDA using gated 3D color flow was achieved in 78.5% of the patients. Nevertheless the use of 3D echocardiogram in assessment of small vascular structures like PDA in children with rapid heart rates is still of limited clinical value.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3727490PMC
http://dx.doi.org/10.1016/j.jsha.2012.02.001DOI Listing

Publication Analysis

Top Keywords

anatomical type
12
patent ductus
8
ductus arteriosus
8
echocardiogram angiography
8
echocardiogram
6
visualization patent
4
arteriosus real-time
4
real-time three-dimensional
4
three-dimensional echocardiogram
4
echocardiogram comparative
4

Similar Publications

Background And Purpose: To evaluate various anatomical parameters and their relationship to chorda tympani nerve (CTN) injury and round window (RW) access during cochlear implantation.

Materials And Methods: Ultra-high-resolution CT images of 66 patients were retrospectively reviewed and compared with operative reports. The facial recess and the round window were analyzed, mainly using the chorda-facial angle (CFA), the width of the facial recess, the CTN-tympanic annulus distance, the RW-mastoid portion of the facial nerve angle, and the type of RW.

View Article and Find Full Text PDF

Purpose: The aim of this study is to obtain the anatomical limits of the parapharyngeal space by transoral surgical approach, in order to objectively determine the types of lesions according to location, where this type of approach is more indicated.

Methods: A prospective, experimental, radio-anatomical study was performed on 10 cryopreserved human heads(20 sides). A transoral approach of the parapharyngeal space was performed determining its anatomical limits by CT navigation.

View Article and Find Full Text PDF

A multicenter study of neurofibromatosis type 1 utilizing deep learning for whole body tumor identification.

NPJ Digit Med

January 2025

Neurofibromatosis Type 1 Center and Laboratory for Neurofibromatosis Type 1 Research, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200011, China.

Deep-learning models have shown promise in differentiating between benign and malignant lesions. Previous studies have primarily focused on specific anatomical regions, overlooking tumors occurring throughout the body with highly heterogeneous whole-body backgrounds. Using neurofibromatosis type 1 (NF1) as an example, this study developed highly accurate MRI-based deep-learning models for the early automated screening of malignant peripheral nerve sheath tumors (MPNSTs) against complex whole-body background.

View Article and Find Full Text PDF

Background: There has been an increase in both primary anatomic (aTSA) and reverse total shoulder arthroplasty (rTSA) over the last decade, with rates peaking for patients aged 75 years and older. Despite aTSA being the mainstay of treatment for patients with glenohumeral arthritis in the absence of rotator cuff insufficiency, there has been an upward trend of rTSA utilization in the elderly due to concerns about rotator cuff integrity, regardless of deformity. The purpose of this study is to evaluate outcomes including pain, function, range of motion, satisfaction, and complications in patients 80 years or older following primary anatomic and reverse total shoulder arthroplasty for osteoarthritis without full thickness rotator cuff tears.

View Article and Find Full Text PDF

Objective: Our primary objective was to identify and describe demographic trends in head and neck injuries incurred while participating in horseback riding.

Study Design: Cross-sectional analysis.

Setting: National Database.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!