During microvascular anastomosis, it is important to maintain the microsurgical field irrigated yet dry so as to achieve a good view of the vessels for approximation. In this method, an infant feeding tube (size 4), with its tip sandwiched between layers of dry gauze and a surgical glove component placed in the anastomotic field and the other end connected to a suction apparatus, is used to maintain the microsurgical field free from flooding. It also has the additional advantage of providing a stable platform for microvascular anastomosis.