In cardiac imaging with 201Tl, the collimator for low energy high resolution is generally used, and also the energy window, which is set on the spectral display of a pulse height analyzer of a scintillation camera, is chosen 70 +/- 12.5 keV. The purpose of this study is to discuss those conditions in 201Tl imaging with the scintillation camera. Two types of collimators for HR (high resolution) and ME (medium energy) were used in this experiment, and we measured the pulse height spectra of 201TlCl radiopharmaceuticals in air and in a cuboid phantom, connecting a multi-channel pulse height analyzer to the scintillation camera. As a result of measuring of the pulse height spectra, two different energies of gamma rays which are not supposed to emit from 201Tl nuclide were observed, and we also identified the presence of a small amount of 202Tl (with 439 keV) and/or 200Tl (with 368 keV) from their half-life measurements. Thus, the use of the HR-collimator with 201Tl imaging is not suitable, because the shielding effects of its septa is poor to 439 keV gamma-rays, and the scattered radiation produced by the Compton interaction contributes to the principal photopeak on the pulse height spectrum. Here, we recommend the use ME-collimator instead of the HR-one, and of the window width of 76 +/- 25 keV for increasing the count rate.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3769/radioisotopes.39.6_255 | DOI Listing |
PLoS One
January 2025
Graduate School of Education & Human Development, Nagoya University, Nagoya, Aichi, Japan.
The present study examined factors associated with trunk skeletal muscle thickness (MT, an index for the amount of skeletal muscle) and echo intensity (EI, an index for the content of non-contractile tissue, such as intramuscular adipose tissue) in young Japanese men and women in consideration of habitual dietary intake. Healthy men (n = 26) and women (n = 24) aged 20 to 26 were enrolled. Trunk MT and EI were evaluated using ultrasound imaging at the height of the 3rd lumbar vertebra.
View Article and Find Full Text PDFAndes Pediatr
August 2024
Departamento de Ciencias de la Actividad Física, Universidad Católica del Maule, Talca, Chile.
Unlabelled: Cardiorespiratory fitness can be assessed by direct, indirect, maximal, and moderate effort, running, cycling, or walking methods.
Objective: To predict maximum oxygen consumption (V O2max) from the six-minute walk test in schoolchildren.
Patients And Method: 459 students were included, 215 were male and 244 were female, aged 11.
J Sci Med Sport
December 2024
Institute of Sports and Sports Science, Karlsruhe Institute of Technology, Germany; TSG ResearchLab gGmbH, Germany.
Objectives: This study aimed to assess relationships of acute responses to short-format high-intensity interval training (HIIT) with the anaerobic speed reserve (ASR) of adolescent runners.
Design: Pre-post intervention design.
Methods: Eighteen highly-trained youth runners (15.
J Bone Miner Res
January 2025
Departments of Medicine and Radiology, University of Manitoba, Winnipeg, Canada.
Vertebral fracture assessment (VFA) images from bone density machines enable the automated machine learning assessment of abdominal aortic calcification (ML-AAC), a marker of cardiovascular disease (CVD) risk. The objective of this study was to describe the risk of a major adverse cardiovascular event (MACE, from linked health records) in patients attending routine bone mineral density (BMD) testing and meeting specific criteria based on age, BMD, height loss, or glucocorticoid use have a VFA in the Manitoba Bone Mineral Density Registry. The cohort included 10 250 individuals (mean 75.
View Article and Find Full Text PDFSci Rep
January 2025
Laboratory of Nutrition and Physical Activity Research (LABINAF), Institute of Nutrition and Food Technology (INTA), University of Chile, Santiago, Chile.
Cardiorespiratory fitness is the most important variable related to health and a strong predictor of mortality. However, it is rarely used in clinics due to costs, specialized equipment, space needs, and the requirements of expert staff such as an exercise physiologist, physician, or other health professional. This work aims to validate and test the reliability of a submaximal step test to estimate VOmax of 8-to 16-year-old pediatric populations as a simple and low-cost tool for clinical practice.