Immediate placement of dental implants in the mandible.

J Pharm Bioallied Sci

Department of Prosthodontia, Farooqia Dental College and Hospital, Mysore, Karnataka, India.

Published: July 2013

This case describes extraction of teeth in the mandibular arch, i.e., 41 42 43 44 45 51 52 53 54 55 56 57 58 (grade two mobility), followed by immediate placement of four dental implants (3i biomet), two in the 45 55 region and two dental implants in 12 21 region. A prefabricated provisional mandibular denture was immediately placed. The purpose of immediate placement was to aid the patient resume his professional duties the next day itself along with esthetic and functional comfort, psychological well-being and most importantly preserving the remaining tissue in a healthy condition.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3740663PMC
http://dx.doi.org/10.4103/0975-7406.114311DOI Listing

Publication Analysis

Top Keywords

dental implants
12
placement dental
8
implants mandible
4
mandible case
4
case describes
4
describes extraction
4
extraction teeth
4
teeth mandibular
4
mandibular arch
4
arch grade
4

Similar Publications

LIPUS promotes osteogenic differentiation of rat BMSCs and osseointegration of dental implants by regulating ITGA11 and focal adhesion pathway.

BMC Oral Health

January 2025

Beijing Institute of Dental Research, Beijing Stomatological Hospital, School of Stomatology, Capital Medical University, Beijing, China.

Background: Low-intensity pulsed ultrasound (LIPUS) has been used as an effective noninvasive method for treating fractures and osteoarthrosis, but the application in the field of oral implantation is in its infancy. This study aimed to clarify the effect and mechanism of LIPUS on the osteogenic differentiation of bone marrow mesenchymal stem cells (BMSCs) and implant osseointegration, and to provide an experimental basis for future clinical applications.

Methods: Dental implants were inserted into Wistar rat femurs, and LIPUS was performed for 4 weeks.

View Article and Find Full Text PDF

Introduction: Soft-tissue defect is commonly seen in immediate maxillary posterior implantation because of tooth extraction wound and tension from bone graft. Bone graft materials exposure has a significant detrimental influence on bone augmentation. However, previous studies lack sufficient evidence to guide wound closure after immediate posterior implantation.

View Article and Find Full Text PDF

Statement Of Problem: Although immediate implant loading has shown promising clinical results and high survival rates, an increased risk of implant failure and complications has been reported. Achieving consistently predictable outcomes with this approach remains a challenge, but evidence-based guidelines to assist in selecting suitable patients are lacking.

Purpose: The purpose of this retrospective clinical study was to investigate the success rate, survival rate, and complications of immediate implant loading compared with early and delayed loading.

View Article and Find Full Text PDF

Accuracy of robot-assisted implant surgery versus freehand placement: a retrospective clinical study.

Int J Implant Dent

January 2025

Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, China.

Purpose: This study evaluated the accuracy of implant placement using a robotic system (Remebot) compared to freehand surgery and explored factors influencing accuracy.

Methods: This retrospective study included 95 implants placed in 65 patients, divided into robot-assisted (50 implants) and freehand (45 implants) groups. Platform, apical, and angular deviations were measured by superimposing preoperative plans and the postoperative CBCT images.

View Article and Find Full Text PDF

Aim: The aim is to evaluate and compare stress distribution characteristics of ball, magnet, and positioned attachment systems in single and double implant-retained overdentures using the finite element method (FEM).

Setting And Design: In vitro (in silico study) finite element analysis (FEA).

Materials And Methods: A Styrofoam mandible with duplicated silicon mucosa was used to construct a mandibular complete denture.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!