Aim: This aim of this study was to evaluate the number of bacteria extruded apically during root canal preparation using Four Rotary instrumentation techniques.
Materials And Methods: A total of 50 extracted mandibular premolars were selected, access cavities prepared and inserted in to rubber stoppers of 10 mL glass vial. Root canals were contaminated with a suspension of Enterococcus faecalis (E. faecalis) American Type Culture Collection (ATCC) 29212 and incubated for 24 h at 37°C. Debris extruded from the apical foramen during instrumentation was collected into vials. The numbers of Colony-forming units were determined for each sample.
Statistical Analysis: The data obtained were analyzed using the one-way ANOVA followed by post-hoc tukey's test with a P = 0.05 as the level for statistical significance.
Results: Results suggested a statistically significant difference in the number of colony forming units between four experimental rotary Nickel-Titanium instrumentation groups (P < 0.001).
Conclusion: Although, extrusion of bacteria was found in all the experimental groups. There was less bacterial extrusion in K3 Group while more bacterial extrusion was seen in Mtwo Group.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3740638 | PMC |
http://dx.doi.org/10.4103/0972-0707.114353 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!