Amputee locomotion: spring-like leg behavior and stiffness regulation using running-specific prostheses.

J Biomech

Japan Society for the Promotion of Science, Tokyo, Japan; Department of Kinesiology, University of Maryland, College Park, MD, USA.

Published: September 2013

Carbon fiber running-specific prostheses (RSPs) have allowed individuals with lower extremity amputation (ILEA) to participate in running. It has been established that as running speed increases, leg stiffness (Kleg) remains constant while vertical stiffness (Kvert) increases in able-bodied runners. The Kvert further depends on a combination of the torsional stiffnesses of the joints (joint stiffness; Kjoint) and the touchdown joint angles. Thus, an increased understanding of spring-like leg function and stiffness regulation in ILEA runners using RSPs is expected to aid in prosthetic design and rehabilitation strategies. The aim of this study was to investigate stiffness regulation to various overground running speeds in ILEA wearing RSPs. Eight ILEA performed overground running at a range of running speeds. Kleg, Kvert and Kjoint were calculated from kinetic and kinematic data in both the intact and prosthetic limbs. Kleg and Kvert in both the limbs remained constant when running speed increased, while intact limbs in ILEA running with RSPs have a higher Kleg and Kvert than residual limbs. There were no significant differences in Kankle, Kknee and touchdown knee angle between the legs at all running speeds. Hip joints in both the legs did not demonstrate spring-like function; however, distinct impact peaks were observed only in the intact leg hip extension moment at the early stance phase, indicating that differences in Kvert between limbs in ILEA are due to attenuating shock with the hip joint. Therefore, these results suggest that ILEA using RSPs has a different stiffness regulation between the intact and prosthetic limbs during running.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3786338PMC
http://dx.doi.org/10.1016/j.jbiomech.2013.07.009DOI Listing

Publication Analysis

Top Keywords

stiffness regulation
16
running speeds
12
kleg kvert
12
running
9
spring-like leg
8
running-specific prostheses
8
running speed
8
overground running
8
intact prosthetic
8
prosthetic limbs
8

Similar Publications

Biochips are widely applied to manipulate the geometrical morphology of stem cells in recent years. Patterned antenna-like pseudopodia are also probed to explore the influence of pseudopodia formation on gene delivery and expression on biochips. However, how the antenna-like pseudopodia affect gene transfection is unsettled and the underlying trafficking mechanism of exogenous genes in engineered single cells is not announced.

View Article and Find Full Text PDF

The elongation of tissues and organs is important for proper morphogenesis in animal development. In Drosophila ovaries, the elongation of egg chambers involves aligned Collagen IV fiber-like structures, a gradient of extracellular matrix stiffness and actin-based protrusion-driven collective cell migration, leading to the rotation of the egg chamber. Egg chamber elongation and rotation depend on the atypical cadherin Fat2.

View Article and Find Full Text PDF

Aims: Hepcidin regulates plasma and tissue iron levels. We studied the association of hepcidin levels with the risk of incident heart failure (HF) and cardiac dysfunction in older adults.

Methods: We included adults from the ongoing, longitudinal Atherosclerosis Risk in Communities (ARIC) study who were free from prevalent anemia and HF at Visit 5 (2011-2013) and had available hepcidin and covariate data.

View Article and Find Full Text PDF

Tubulin Acetylation Enhances Microtubule Stability in Trabecular Meshwork Cells Under Mechanical Stress.

Invest Ophthalmol Vis Sci

January 2025

Department of Ophthalmology, Duke Eye Center, Duke University, Durham, North Carolina, United States.

Purpose: To study the roles of tubulin acetylation and cyclic mechanical stretch (CMS) in trabecular meshwork (TM) cells and their impact on outflow pathway physiology and pathology.

Methods: Primary TM cell cultures were subjected to CMS (8% elongation, 24 hours), and acetylated α-tubulin at lysine 40 (Ac-TUBA4) was assessed by western blotting and immunofluorescence. Enzymes regulating tubulin acetylation were identified via siRNA-mediated knockdowns of ATAT1, HDAC6, and SIRT2.

View Article and Find Full Text PDF

Assessing the impact of e-cigarettes on human barrier systems: A systematic review.

Transl Res

January 2025

Occupational Medicine, Department of Clinical and Experimental Medicine, University of Catania, 95124 Catania, Italy. Electronic address:

The use of e-cigarettes has grown rapidly in recent years, raising concerns about their impact on human health, particularly on critical physiological barriers such as the blood-brain barrier (BBB), alveolar-capillary barrier, and vascular systems. This systematic review evaluates the current literature on the effects of e-cigarette exposure on these barrier systems. E-cigarettes, regardless of nicotine content, have been shown to induce oxidative stress, inflammation, and disruption of tight junction proteins, leading to impaired barrier function.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!