Some hazards posed by the operation of hydraulic systems, connected with low-frequency vibrations and noise are presented. Special attention is focused on infrasounds. The sources of low-frequency vibrations and noise and ways of reducing them are indicated. An original solution ensuring the effective reduction of vibrations and noise in a wide frequency range, i.e., a wide-band damper of pressure fluctuations, also performing the function of an acoustic filter, is proposed. The effectiveness of the damper was confirmed by the results of laboratory tests and tests carried out on engineering machines working in real conditions.
Download full-text PDF |
Source |
---|
Sensors (Basel)
January 2025
Laboratory of Vibration and Noise, Naval University of Engineering, Wuhan 430033, China.
Pulsation noise in the piping system generated by the excitation of the pump source seriously affects the reliability of the pipeline system and mechanical equipment. The active noise control can effectively suppress the low-frequency noise in the liquid-filled pipeline. Active control methods with intrusive secondary sources generally use dynamic pressure sensors or hydrophones to collect signals, which destroy the structure of the pipe.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Institute of Semiconductor Technology (IHT), Technische Universität Braunschweig, Hans-Sommer-Straße 66, 38106 Braunschweig, Germany.
A novel piezoresistive cantilever microprobe (PCM) with an integrated electrothermal or piezoelectric actuator has been designed to replace current commercial PCMs, which require external actuators to perform contact-resonance imaging (CRI) of workpieces and avoid unwanted "forest of peaks" observed at large travel speed in the millimeter-per-second range. Initially, a PCM with integrated resistors for electrothermal actuation (ETA) was designed, built, and tested. Here, the ETA can be performed with a piezoresistive Wheatstone bridge, which converts mechanical strain into electrical signals by boron diffusion in order to simplify the production process.
View Article and Find Full Text PDFFront Neurosci
January 2025
School of Electronic Information and Communications, Huazhong University of Science and Technology, Wuhan City, China.
Introduction: Transcranial magnetic stimulation (TMS) is widely used for the noninvasive activation of neurons in the human brain. It utilizes a pulsed magnetic field to induce electric pulses that act on the central nervous system, altering the membrane potential of nerve cells in the cerebral cortex to treat certain mental diseases. However, the effectiveness of TMS can be compromised by significant heat generation and the clicking noise produced by the pulse in the TMS coil.
View Article and Find Full Text PDFRev Sci Instrum
January 2025
OzGrav-ANU, ARC Centre for Gravitational Astrophysics, College of Science, The Australian National University, Canberra ACT2601, Australia.
We present the design and commissioning of a cryogenic low-vibration test facility that measures displacement noise from a gram-scale silicon cantilever at the level of 10-16m/Hz at 1 kHz. This sensitivity is necessary for future tests of thermal noise models on cross sections of silicon suspension samples proposed for future gravitational-wave detectors. A volume of ∼36 l is enclosed by radiation shields cooling an optical test cavity that is suspended from a multi-stage pendulum chain providing isolation from acoustic and environmental noise.
View Article and Find Full Text PDFSpectrochim Acta A Mol Biomol Spectrosc
January 2025
Laboratory for Spectroscopy, Molecular Modeling and Structure Determination, Institute of Nuclear Chemistry and Technology, 16 Dorodna Street, 03-195 Warsaw, Poland. Electronic address:
The Raman spectra of lanthanide [Ln(HO)(Ala)](ClO) crystals were measured with 488, 532, 633, and 1064 nm laser lines, and ROA of complexes in water were collected using 532 nm excitation. As in IR and VCD, ν(CO) stretching and β(OCO) bending vibration bands showed a tendency typical to the lanthanide contraction effect. However, in Raman, the effect is less pronounced than the IR spectrum because it is strongly perturbed by lanthanide ion luminescence, which comes from the 4f → 4f transitions.