A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Pulsatile stent graft: a new alternative in chronic ventricular assistance. | LitMetric

Objective: Heart failure is currently one of the most common hospitalization causes. Several chronic circulatory assist devices have been tested and are highly complex. The objective is the description of a pulsatile endoprosthesis capable of applying a chronic pulse within the descending aorta, similar to that produced by intra-aortic balloon.

Methods: Pulsatile stents composed of nickel-titanium were built and positioned to engage latex tubes simulating the aorta. Different electric currents were applied to units connected in series in order to cause structure contraction and displacement of a liquid column. There were two sequence tests: first composed of two metallic cages and the second composed of five cages. At first sequence tests was applied a voltage of 16.3 volts and a current of 5 amperes. In the second, voltage of 15 volts and current of 07 amperes.

Results: In the first sequence was obtained the pulsatile effect of stent, with contraction of the tube and displacement of the water column sufficient to validate the pulsating effect of the endoprosthesis. The two structures ejected a volume of 2.6 ml per cycle, with a range of 29 mm in height of the column of water equivalent to 8% shrinkage during the pulse. In the second sequence, it reachead a variation of 7.4 mL per cycle.

Conclusion: The results obtained confirm the stent pulsatile contractility activated by electrical current. The continuity of the study and material improvement are necessary to obtain more efficient model from the point of view of energy and pulse, to allow ejection volumes comparable with the intra-aortic balloons.

Download full-text PDF

Source
http://dx.doi.org/10.5935/1678-9741.20130031DOI Listing

Publication Analysis

Top Keywords

pulsatile stent
8
sequence tests
8
volts current
8
pulsatile
5
stent graft
4
graft alternative
4
alternative chronic
4
chronic ventricular
4
ventricular assistance
4
assistance objective
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!