We propose a noniterative data inversion process for the phase retrieval by omega oscillating filtering method that could measure both isolated attosecond pulses and periodic optical arbitrary waveform (OAW). The built-in phase modulation depth recovery not only prevents the need of independent calibration (a critical advantage in the extreme ultraviolet regime) but provides a self-consistency check for the data integrity. Our experiments successfully retrieved OAW with ~100% duty cycle in the near infrared regime.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.38.002011DOI Listing

Publication Analysis

Top Keywords

noniterative data
8
data inversion
8
phase retrieval
8
retrieval omega
8
omega oscillating
8
oscillating filtering
8
optical arbitrary
8
arbitrary waveform
8
inversion phase
4
filtering optical
4

Similar Publications

Model-Implied Instrumental Variable Two-Stage Least Squares (MIIV-2SLS) is a limited information, equation-by-equation, non-iterative estimator for latent variable models. Associated with this estimator are equation specific tests of model misspecification. One issue with equation specific tests is that they lack specificity, in that they indicate that some instruments are problematic without revealing which specific ones.

View Article and Find Full Text PDF

Advanced Charge Extended Hückel (CEH) Model and a Consistent Adaptive Minimal Basis Set for the Elements = 1-103.

J Phys Chem A

December 2024

Mulliken Center for Theoretical Chemistry, Clausius-Institute for Physical and Theoretical Chemistry, University of Bonn, Beringstraße 4, Bonn 53115, Germany.

The Charge Extended Hückel (CEH) model, initially introduced for adaptive atomic orbital (AO) basis set construction ( , 159, 164108), has been significantly revised to enhance accuracy and robustness, particularly in challenging electronic situations. This revision includes an extension toward -elements, covering actinoids with their -electrons in the valence space. We present a novel noniterative approximation for the electrostatic contribution to the effective Fock matrix, which substantially improves performance in polar or charged systems.

View Article and Find Full Text PDF

Structured illumination microscopy (SIM) is a widely applied fluorescence super-resolution imaging technique. It can also serve as high-throughput imaging in coherent imaging systems. However, coherent SIM requires additional qualitative/quantitative phase imaging methods to acquire phase information.

View Article and Find Full Text PDF

National and international biobanking efforts led to the collection of large and inclusive imaging genetics datasets that enable examination of the contribution of genetic and environmental factors to human brains in illness and health. High-resolution neuroimaging (~10 voxels) and genetic (10 single nucleotide polymorphic [SNP] variants) data are available in statistically powerful (N = 10) epidemiological and disorder-focused samples. Performing imaging genetics analyses at full resolution afforded in these datasets is a formidable computational task even under the assumption of unrelatedness among the subjects.

View Article and Find Full Text PDF

Non-iterative model-based inversion for low channel-count optical ultrasound imaginga).

J Acoust Soc Am

November 2024

Department of Medical Physics & Biomedical Engineering, University College London, London, WC1E 6BT, United Kingdom.

Article Synopsis
  • Ultrasound imaging often uses a fast delay-and-sum algorithm, but this can cause image issues with low channel count systems.
  • Model-based inversion methods can reduce these artefacts but usually require high computational resources, making real-time use challenging.
  • The presented direct model-based inversion (DMI) method for optical ultrasound (OpUS) showed significant improvements in image quality and speed, making it viable for other low channel-count imaging systems as well.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!