Prechemistry nucleotide selection checkpoints in the reaction pathway of DNA polymerase I and roles of glu710 and tyr766.

Biochemistry

Department of Molecular Biophysics and Biochemistry, Yale University, New Haven, Connecticut 06520, United States.

Published: September 2013

The accuracy of high-fidelity DNA polymerases such as DNA polymerase I (Klenow fragment) is governed by conformational changes early in the reaction pathway that serve as fidelity checkpoints, identifying inappropriate template-nucleotide pairings. The fingers-closing transition (detected by a fluorescence resonance energy transfer-based assay) is the unique outcome of binding a correct incoming nucleotide, both complementary to the templating base and with a deoxyribose (rather than ribose) sugar structure. Complexes with mispaired dNTPs or complementary rNTPs are arrested at an earlier stage, corresponding to a partially closed fingers conformation, in which weak binding of DNA and nucleotide promote dissociation and resampling of the substrate pool. A 2-aminopurine fluorescence probe on the DNA template provides further information about the steps preceding fingers closing. A characteristic 2-aminopurine signal is observed on binding a complementary nucleotide, regardless of whether the sugar is deoxyribose or ribose. However, mispaired dNTPs show entirely different behavior. Thus, a fidelity checkpoint ahead of fingers closing is responsible for distinguishing complementary from noncomplementary nucleotides and routing them toward different outcomes. The E710A mutator polymerase has a defect in the early fidelity checkpoint such that some complementary dNTPs are treated as if they were mispaired. In the Y766A mutant, the early checkpoint functions normally, but some correctly paired dNTPs do not efficiently undergo fingers closing. Thus, both mutator alleles cause a blurring of the distinction between correct and incorrect base pairs and result in a larger fraction of errors passing through the prechemistry fidelity checkpoints.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3770053PMC
http://dx.doi.org/10.1021/bi400837kDOI Listing

Publication Analysis

Top Keywords

fingers closing
12
reaction pathway
8
dna polymerase
8
fidelity checkpoints
8
deoxyribose ribose
8
mispaired dntps
8
fidelity checkpoint
8
dna
5
complementary
5
prechemistry nucleotide
4

Similar Publications

Prcis: In the real-world, retrospective, EXPAND study of consecutive adults with glaucoma, ab-externo gel stent implantation effectively lowered intraocular pressure (34%) and the medication burden (61%), with transient/self-resolving hypotony as the most frequent adverse event (28%).

Purpose: To assess effectiveness and safety of ab-externo gel stent (GS) implantation in glaucoma.

Methods: Multicenter, real-world, retrospective study.

View Article and Find Full Text PDF

Introduction: Ultrasonography is increasingly used to diagnose the carpal tunnel syndrome (CTS). Most frequently, the enlargement of the nerve cross-sectional area (CSA) at the tunnel inlet serves to confirm the diagnosis. Recent research has shown that the nerve diameter is decreased within the tunnel, when measured at the level of pisiforme or capitatum.

View Article and Find Full Text PDF

This paper describes the production and high-current-density hydrogen evolution reaction (HER) performance in the whole pH range (from acidic to basic pH values) of self-supported α-MoB/β-MoB ceramic electrodes, aiming for use in industrial electrocatalytic water splitting. Tape-casting and phase-inversion process, followed by sintering, were employed to synthesize self-supported β-MoB ceramic electrodes, which exhibited well arranged large finger-like pores, providing numerous active sites and channels for electrolyte entry and hydrogen release. The reaction between β-MoB and the sintering aid of MoO produces α-MoB/β-MoB heterojunctions, which significantly improve the electrocatalytic performance.

View Article and Find Full Text PDF

Wearable motion capture gloves enable the precise analysis of hand and finger movements for a variety of uses, including robotic surgery, rehabilitation, and most commonly, virtual augmentation. However, many motion capture gloves restrict natural hand movement with a closed-palm design, including fabric over the palm and fingers. In order to alleviate slippage, improve comfort, reduce sizing issues, and eliminate movement restrictions, this paper presents a new low-cost data glove with an innovative open-palm and finger-free design.

View Article and Find Full Text PDF

Heart rate variability as a digital biomarker for frailty in cardiovascular patients.

J Frailty Aging

February 2025

Division of Experimental Medicine, McGill University, Montreal, QC Canada; Division of Cardiology, Jewish General Hospital, Montreal, QC Canada. Electronic address:

Background: Frailty is a syndrome associated with age-related impairments in multiple organ systems, of which the autonomic nervous system plays a fundamental role. Measurement of heart rate variability (HRV) is a non-invasive method to evaluate the autonomic activity and gain insights into cardiovascular health and potentially, frailty. A few small studies have explored the relationship between HRV and frailty, with promising but conflicting results.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!