Adaptive optics imaging of parafoveal cones in type 1 diabetes.

Retina

*Fondazione G.B. Bietti IRCCS, Rome, Italy; †CNR-IPCF Unit of Support Cosenza, University of Calabria, Rende, Italy; and ‡Vision Engineering, Rome, Italy.

Published: March 2014

Purpose: To evaluate the parafoveal cone density in patients with Type 1 diabetes mellitus (DM1).

Methods: Adaptive optics retinal images of the photoreceptor mosaic were acquired from 11 DM1 patients (study group) and 11 age-matched healthy subjects (control group). Cone density was analyzed, along the horizontal and vertical meridian, at 230-µm, 350-µm, and 460-µm eccentricity from the fovea. Central retinal thickness was measured using a Spectralis spectral-domain optical coherence tomography. A multiple regression model was performed to determine the relationships between the explanatory variables (age, glycohemoglobin level, presence of diabetic retinopathy, duration of diabetes, and central retinal thickness) and cone density.

Results: Patients had a diagnosis of DM1 in the past 9 years to 21 years. Of these, five patients had a diagnosis of no diabetic retinopathy and six had mild nonproliferative diabetic retinopathy. On average, cone density was 10% lower in the study than in the control group at each retinal eccentricity along the horizontal and vertical meridians (analysis of variance, P < 0.001). The central retinal thickness was thicker in DM1 eyes than in the control eyes (278 ± 20 µm and 260 ± 13 µm; P < 0.05). The model explained 61% (P < 0.01) of the variance of cone density in the population, with the variables representing an abnormal glucose metabolism, that is, a higher glycohemoglobin level, the presence of diabetic retinopathy, and a chronic diabetes, having the highest influence on cone density decline.

Conclusion: A subtle decrease of parafoveal cone density was found in DM1 patients in comparison with age-matched control subjects via high-resolution adaptive optics retinal imaging. The cone density decline was moderately associated with a disturbance in the glucose metabolism.

Download full-text PDF

Source
http://dx.doi.org/10.1097/IAE.0b013e3182a10850DOI Listing

Publication Analysis

Top Keywords

cone density
28
diabetic retinopathy
16
adaptive optics
12
central retinal
12
retinal thickness
12
type diabetes
8
cone
8
parafoveal cone
8
optics retinal
8
dm1 patients
8

Similar Publications

Aim: To study the dosimetric behavior of dose computational algorithms in inhomogeneous medium using CMS XiO and MONACO treatment planning system (TPS) for 4 megavoltage (MV), 6 MV and 15 MV photon beam energies.

Material And Methods: Styrofoam blocks of thickness 1.90 cm, 3.

View Article and Find Full Text PDF

Microtextured microneedles are tiny needle-like structures with micron-scale microtextures, and the drugs stored in the microtextures can be released after entering the skin to achieve the effect of precise drug delivery. In this study, the skin substitution model of Ogden's hyperelastic model and the microneedle array and microtexture models with different geometrical parameters were selected to simulate and analyse the flow of the microtexture microneedle arrays penetrating the skin by the finite-element method, and the length of the microneedles was determined to be 200 μm, the width 160 μm, and the value of the gaps was determined to be 420 μm. A four-pronged cone was chosen as the shape of microneedles, and a rectangle was chosen as the shape of the drug-carrying microneedle.

View Article and Find Full Text PDF

Assessment of Photoreceptor Recovery and Visual Function Utilizing Adaptive Optics and Microperimetry in Patients with Surgically Closed Macular Holes.

Photodiagnosis Photodyn Ther

December 2024

Department of Ophthalmology, Tianjin Medical University General Hospital, Tianjin, China, Ministry of Education International Joint Laboratory of Ocular Diseases, Tianjin, China, Tianjin Key Laboratory of Ocular Trauma, Tianjin, China, Tianjin Institute of Eye Health and Eye Diseases, Tianjin, China, China-UK "Belt and Road" Ophthalmology. Electronic address:

Background: This study investigated the association between photoreceptor structural restoration and visual function outcomes in patients undergoing surgery for closed macular holes (MHs). Using adaptive optics scanning laser ophthalmoscopy (AOSLO) and microperimetry, we aimed to provide a more detailed understanding of photoreceptor recovery and visual improvement in closed MHs.

Methods: We conducted a retrospective observational study of 31 eyes of 28 patients who underwent vitrectomy with internal limiting membrane (ILM) peeling to treat idiopathic MHs.

View Article and Find Full Text PDF

Purpose: To evaluate the image quality of an ultrafast cone-beam computed tomography (CBCT) system-Varian HyperSight.

Methods And Materials: In this evaluation, 5 studies were performed to assess the image quality of HyperSight CBCT. First, a HyperSight CBCT image quality evaluation was performed and compared with Siemens simulation-CT and Varian TrueBeam CBCT.

View Article and Find Full Text PDF

Introduction: Cases involving invasive cervical root resorption (ICRR) in oncological patients are rare, in addition, follow-up of these patients has not yet been reported in the literature.

Objective: This study aims to present a literature review and report a case of denosumab as a possible cause of ICRR in a patient with breast cancer with 2 years of follow-up.

Case Report: A 39-year-old female with a history of luminal breast cancer was treated with denosumab semiannually for osteopenia with discontinuation 1 year ago.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!