Phase-shift perfluorocarbon agents enhance high intensity focused ultrasound thermal delivery with reduced near-field heating.

J Acoust Soc Am

Department of Biomedical Engineering, University of North Carolina at Chapel Hill, 109 Mason Farm Road, 304 Taylor Hall, CB 7575, Chapel Hill, North Carolina 27599, USA.

Published: August 2013

Ultrasound contrast agents are known to enhance high intensity focused ultrasound (HIFU) ablation, but these perfluorocarbon microbubbles are limited to the vasculature, have a short half-life in vivo, and may result in unintended heating away from the target site. Herein, a nano-sized (100-300 nm), dual perfluorocarbon (decafluorobutane/dodecafluoropentane) droplet that is stable, is sufficiently small to extravasate, and is convertible to micron-sized bubbles upon acoustic activation was investigated. Microbubbles and nanodroplets were incorporated into tissue-mimicking acrylamide-albumin phantoms. Microbubbles or nanodroplets at 0.1 × 10(6) per cm(3) resulted in mean lesion volumes of 80.4 ± 33.1 mm(3) and 52.8 ± 14.2 mm(3) (mean ± s.e.), respectively, after 20 s of continuous 1 MHz HIFU at a peak negative pressure of 4 MPa, compared to a lesion volume of 1.0 ± 0.8 mm(3) in agent-free control phantoms. Magnetic resonance thermometry mapping during HIFU confirmed undesired surface heating in phantoms containing microbubbles, whereas heating occurred at the acoustic focus of phantoms containing the nanodroplets. Maximal change in temperature at the target site was enhanced by 16.9% and 37.0% by microbubbles and nanodroplets, respectively. This perfluorocarbon nanodroplet has the potential to reduce the time to ablate tumors by one-third during focused ultrasound surgery while also safely enhancing thermal deposition at the target site.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3745500PMC
http://dx.doi.org/10.1121/1.4812866DOI Listing

Publication Analysis

Top Keywords

focused ultrasound
12
target site
12
microbubbles nanodroplets
12
agents enhance
8
enhance high
8
high intensity
8
intensity focused
8
phantoms microbubbles
8
microbubbles
5
phase-shift perfluorocarbon
4

Similar Publications

Background: Short peripheral catheter (SPC) placement is a routine invasive procedure in clinical settings that is crucial for administering fluids, medications, or blood components. Approximately 11% of adult patients arriving at the Emergency Department (ED) experience difficulties with intravenous access (DIVA), necessitating advanced techniques for successful placement. The Enhanced Adult DIVA (EA-DIVA) score serves as a validated tool to promptly identify patients with DIVA.

View Article and Find Full Text PDF

Neurocysticercosis (NCC) is caused by the invasion of larvae in the central nervous system (CNS) and stands as the predominant cause of epilepsy and other neurological disorders in many developing nations. NCC diagnosis is challenging because it relies on brain imaging exams (CT or MRI), which are poorly available in endemic rural or resource-limited areas. Moreover, some NCC cases cannot be easily detected by imaging, leading to inconclusive results.

View Article and Find Full Text PDF

Dirofilariasis, caused by the nematode spp., poses significant challenges in diagnosis due to its diverse clinical manifestations and complex life cycle. This comprehensive literature review focuses on the evolution of diagnostic methodologies, spanning from traditional morphological analyses to modern emerging techniques in the context of dirofilariasis diagnosis.

View Article and Find Full Text PDF

Classification of Severity of Lung Parenchyma Using Saliency and Discrete Cosine Transform Energy in Computed Tomography of Patients With COVID-19.

Int J Telemed Appl

January 2025

Medical Familiar Unit, Instituto de Seguridad y Servicios Sociales de Los Trabajadores del Estado, Torreón, Coahuila, Mexico.

This study proposes an automated system for assessing lung damage severity in coronavirus disease 2019 (COVID-19) patients using computed tomography (CT) images. These preprocessed CT images identify the extent of pulmonary parenchyma (PP) and ground-glass opacity and pulmonary infiltrates (GGO-PIs). Two types of images-saliency () image and discrete cosine transform (DCT) energy image-were generated from these images.

View Article and Find Full Text PDF

Objectives: The current research delves into the use of 3D geometric morphometric for assessing shifts in maturity within both the proximal and distal humeral metaphyses. It mainly focuses on establishing correlations between these shifts and the shape changes observed in the corresponding epiphyses established through radiographic imaging.

Material And Methods: The total sample comprises 120 right-side proximal humeral metaphyses and 91 right-side distal humeral metaphyses.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!