Purpose: This study examined the effects of envelope dynamic-range mismatch on the intelligibility of Mandarin speech in noise by simulated bilateral electric hearing.

Method: Noise-vocoded Mandarin speech, corrupted by speech-shaped noise at 5 and 0 dB signal-to-noise ratios, was presented unilaterally or bilaterally to 10 normal-hearing listeners for recognition. For unilateral conditions, the right ear was presented with the 8-channel noise-vocoded stimuli generated using a 15-dB envelope dynamic range (DR). To simulate the envelope DR mismatch between the 2 ears, the left ear was presented with the 8-channel noise-vocoded stimuli generated using a 5-, 10-, or 15-dB envelope DR, respectively.

Results: Significant binaural summation benefits for Mandarin speech recognition were observed only with matched envelope DR between the 2 ears. With reduced DR, the performance of tone identification was more consistent in the steady-state speech-shaped noise than that of sentence recognition.

Conclusions: Consistent with previous findings, the present results suggest that Mandarin speech-perception performance of bilateral electric listening in noise is affected by the difference of envelope DR between the 2 implanted ears, and the binaural summation benefits are maximized when DR mismatch is minimized between the 2 implanted ears.

Download full-text PDF

Source
http://dx.doi.org/10.1044/1092-4388(2012/12-0255)DOI Listing

Publication Analysis

Top Keywords

bilateral electric
12
mandarin speech
12
matched envelope
8
envelope dynamic
8
dynamic range
8
simulated bilateral
8
speech-shaped noise
8
ear presented
8
presented 8-channel
8
8-channel noise-vocoded
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!