Background: The prevalence of prosthesis-patient mismatch (PPM) and its impact on survival after aortic valve replacement have not been clearly defined. Historically, the presence of PPM was identified from postoperative echocardiograms or preoperative manufacturer-provided charts, resulting in wide discrepancies. The 2009 American Society of Echocardiography (ASE) guidelines proposed an algorithmic approach to calculate PPM. This study compared PPM prevalence and its impact on survival using 3 modalities: (1) the ASE guidelines-suggested algorithm (ASE PPM); (2) the manufacturer-provided charts (M PPM); and (3) the echocardiographically measured, body surface area-indexed, effective orifice area (EOAi PPM) measurement.

Methods And Results: A total of 614 patients underwent aortic valve replacement with bovine pericardial valves from 2004 to 2009 and had normal preoperative systolic function. EOAi PPM was severe if EOAi was ≤ 0.60 cm(2)/m(2), moderate if EOAi was 0.60 to 0.85 cm(2)/m(2), and absent (none) if EOAi was ≥ 0.85 cm(2)/m(2). ASE PPM was severe in 22 (3.6%), moderate in 6 (1%), and absent (none) in 586 (95.4%). ASE PPM was similar to manufacturer-provided PPM (P=1.00). ASE PPM differed significantly from EOAi PPM (P<0.001), which identified severe mismatch in 170 (29.7%), moderate in 191 (33.4%), and absent (none) in 211 patients (36.9%). Irrespective of the PPM classification method, PPM did not adversely affect midterm survival (average follow-up, 4.1 ± 1.8 years; median, 3.9 years; range, 0.01-8 years). There were no reoperations for PPM.

Conclusions: In patients with normal systolic function undergoing bovine pericardial aortic valve replacement, the prevalence of PPM using the algorithmic-ASE approach was low and correlated well with manufacturer-provided PPM. Independent of the method of PPM assessment, PPM was not associated with medium-term mortality.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCIMAGING.112.000319DOI Listing

Publication Analysis

Top Keywords

ase ppm
16
ppm
13
eoai ppm
12
prosthesis-patient mismatch
8
bovine pericardial
8
impact survival
8
aortic valve
8
valve replacement
8
manufacturer-provided charts
8
ppm manufacturer-provided
8

Similar Publications

Decoupling the influence of NO in flue gas on the application of nano-amorphous selenium for mercury removal.

Sci Total Environ

November 2024

State Key Laboratory of Coal Combustion, School of Energy and Power Engineering, Huazhong University of Science and Technology, Wuhan 430074, China. Electronic address:

Nitrogen oxides are inevitable hazardous components in coal-fired flue gas. This study designed a series of experiments and combined theoretical calculations to systematically investigate the effect of NO on the removal of element mercury (Hg) by nano-amorphous selenium (nano-a-Se). It was found that the impact of NO on the removal of Hg by nano-a-Se primarily involves two mechanisms: competitive adsorption between NO and Hg, and the induced reduction effect of NO on chemisorbed mercury (HgSe).

View Article and Find Full Text PDF

A novel, to the best of our knowledge, and compact fiber-optic hydrogen sensor based on light intensity demodulation and controllable optical heating technology is proposed and experimentally investigated. This system employs three photodetectors for optic signal transformation. The first PD is used to receive a little fraction of the amplified spontaneous emission (ASE) for calibration, and the second PD is utilized to detect optic signal reflected by a single mode fiber deposited with WO-PdPt-Pt composite film.

View Article and Find Full Text PDF

The chalcogen-bonded homo-cavitand and hetero-cavitand AY+AY' capsules (Y, Y' = Se, Te), as well as their encapsulated complexes with one or two guest molecules have been studied theoretically density functional theory (DFT), while the H NMR spectra of the homo-cavitand encapsulated complexes (in ASe+ASe) have been measured experimentally. There is excellent agreement between theoretical and experimental spectra. In all cases, we found significant H upfield shifts which are more intense in the ASe+ASe cage compared to the ATe+ATe and ASe+ATe cages.

View Article and Find Full Text PDF

Cottonseed oil: A review of extraction techniques, physicochemical, functional, and nutritional properties.

Crit Rev Food Sci Nutr

March 2023

Jiangsu Provincial Engineering Laboratory for Biomass Conversion and Process Integration, School of Life Science and Food Engineering, Huaiyin Institute of Technology, Huaian, China.

Seed oils are the richest source of vitamin-E-active compounds, which contribute significantly to antioxidant activities. Cottonseed oil (CS-O) is attaining more consideration owing to its high fiber content and stability against auto-oxidation. CS-O has gained a good reputation in the global edible oil market due to its distinctive fatty acid profile, anti-inflammatory, and cardio-protective properties.

View Article and Find Full Text PDF

A green ASE (accelerated solvent extraction) with a shorter UHPLC (ultra-high performance liquid chromatography) method was developed for simultaneous determination of phenolics. High extract yield (130 mg/g) was observed for water at 100 °C in a short time of 19.5 min using 33.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!