The "too-long," or redundant, circumflex graft is notorious for its tendency to form a kink. The acute angle (the kink) typically occurs over the front of the pulmonary trunk. Described herein are (1) the left appendage flip maneuver, a simple solution to correct graft kink, and (2) analysis and explanation of vein graft kink.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1055/s-0033-1351117 | DOI Listing |
Int J Cardiol Heart Vasc
February 2025
Division of Cardiovascular Medicine, Department of Medicine, China Medical University Hospital, China Medical University, Taichung 404327, Taiwan.
Background: The optimal imaging modality for selecting the device size in patients with atrial fibrillation undergoing one-stop left atrial appendage occlusion (LAAO) with concomitant pulmonary vein isolation (PVi) remains undefined. We compared preprocedural 3-dimensional computed tomography (3D CT) with intra-procedural transesophageal echocardiography (TEE) and left atrial appendage (LAA) angiography in guiding one-stage PVi and LAAO.
Methods: We measured the LAA ostium diameter using an interactive 3D CT system with a central line-based approach and compared these measurements with those from intra-procedural TEE and angiography, and the actual device size.
Cureus
December 2024
Cardiology, Avicenna Military Hospital, Marrakesh, MAR.
Introduction Atrial fibrillation (AF), the most common cardiac arrhythmia, poses challenges in predicting thromboembolic risk. While the CHADS-VASc (congestive heart failure, hypertension, age ≥ 75 years (doubled), type 2 diabetes mellitus, previous stroke, transient ischemic attack, or thromboembolism (doubled), vascular disease, age 65-74 years, and sex category) score remains essential, its limitations include failure to identify left atrial (LA) thrombus in some patients. Transesophageal echocardiography (TEE) provides superior detection of LA thrombi and thrombogenic factors compared to transthoracic echocardiography (TTE), improving risk stratification, especially in intermediate-risk groups.
View Article and Find Full Text PDFInt J Cardiol Heart Vasc
February 2025
Department of Cardiology. University Hospital Alvaro Cunqueiro, Vigo, Spain. Galicia Sur Health Research Institute (IIS Galicia Sur). SERGAS-UVIGO.
Introduction And Objectives: Percutaneous left atrial appendage occlusion (LAAO) is a viable option to mitigate bleeding and stroke risks in patients with atrial fibrillation (AF) who are not eligible for oral anticoagulation. Its safety and efficacy in cancer patients remain unclear due to their exclusion from trials. This study aimed to compare short- and long-term LAAO outcomes between cancer and non-cancer patients.
View Article and Find Full Text PDFInt J Cardiol Heart Vasc
February 2025
Department of Internal Medicine I, University Hospital Würzburg, Würzburg, Germany.
Background: Cardioversion, a rhythm control treatment for atrial fibrillation (AF), requires ruling out cardiac embolic sources, often originating from the left atrial appendage (LAA). Transesophageal echocardiography (TEE) is used for LAA evaluation, but it is invasive and not widely available. This study aimed to identify cardiovascular risk factors linked to LAA abnormalities and predictors of thromboembolic events and all-cause mortality.
View Article and Find Full Text PDFBiomech Model Mechanobiol
January 2025
Laboratoire d'Imagerie Biomédicale (LIB), Institut National de La Recherche Médicale (INSERM), Centre National de La Recherche Scientifique (CNRS), Sorbonne Université, Paris, France.
Atrial fibrillation (AF) is characterized by rapid and irregular contraction of the left atrium (LA). Impacting LA haemodynamics, this increases the risk of thrombi development and stroke. Flow conditions preceding stroke in these patients are not well defined, partly due the limited resolution of 4D flow magnetic resonance imaging (MRI).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!