An optically stimulated luminescence dosimeter for measuring patient exposure from imaging guidance procedures.

Phys Med Biol

Department of Radiation Oncology, Vanderbilt University School of Medicine, Vanderbilt-Ingram Cancer Center, B-902, TVC, 1301 Medical Center Drive, Nashville, TN 37232-5671, USA.

Published: September 2013

There is a growing interest in patient exposure resulting from an x-ray imaging procedure used in image-guided radiation therapy. This study explores a feasibility to use a commercially available optically stimulated luminescence (OSL) dosimeter, nanoDot, for estimating imaging radiation exposure to patients. The kilovoltage x-ray sources used for kV-cone-beam CT (CBCT) imaging acquisition procedures were from a Varian on-board imager (OBI) image system. An ionization chamber was used to determine the energy response of nanoDot dosimeters. The chamber calibration factors for x-ray beam quality specified by half-value layer were obtained from an Accredited Dosimetry Calibration Laboratory. The Monte Carlo calculated dose distributions were used to validate the dose distributions measured by using the nanoDot dosimeters in phantom and in vivo. The range of the energy correction factors for the nanoDot as a function of photon energy and bow-tie filters was found to be 0.88-1.13 for different kVp and bow-tie filters. Measurement uncertainties of nanoDot were approximately 2-4% after applying the energy correction factors. The tests of nanoDot placed on a RANDO phantom and on patient's skin showed consistent results. The nanoDot is suitable dosimeter for in vivo dosimetry due to its small size and manageable energy dependence. The dosimeter placed on a patient's skin has potential to serve as an experimental method to monitor and to estimate patient exposure resulting from a kilovoltage x-ray imaging procedure. Due to its large variation in energy response, nanoDot is not suitable to measure radiation doses resulting from mixed beams of megavoltage therapeutic and kilovoltage imaging radiations.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/58/17/5885DOI Listing

Publication Analysis

Top Keywords

patient exposure
12
optically stimulated
8
stimulated luminescence
8
x-ray imaging
8
imaging procedure
8
nanodot
8
kilovoltage x-ray
8
energy response
8
response nanodot
8
nanodot dosimeters
8

Similar Publications

Introduction: Simulation is an educational tool for developing the technical and nontechnical skills of dental students. To optimize learning in simulations, students must be immersed in a high-fidelity environment and emotionally engaged, as is the case in clinical practice. The primary objective of this study was to assess emotions during simulation training and in clinical practice.

View Article and Find Full Text PDF

Superior persistence of ustekinumab compared to anti-TNF in vedolizumab-experienced inflammatory bowel diseases patients: a real-world cohort study.

BMC Gastroenterol

December 2024

Department of Gastroenterology and Hepatology, Linkou Branch, Chang Gung Memorial Hospital, 5, Fu-Hsin Street, Guei-Shan District, Taoyuan, 33305, Taiwan.

Background/aims: The increasing use of biologic therapies for moderate to severe inflammatory bowel disease (IBD) highlights the importance of optimal treatment sequencing, particularly after vedolizumab (VDZ) exposure. Studies comparing the effectiveness of ustekinumab (UST) and antitumor necrosis factor (anti-TNF) agents post-VDZ are limited.

Methods: This retrospective study analyzed VDZ-experienced IBD patients treated with UST or anti-TNF (adalimumab and infliximab) from May 2019 to January 2024.

View Article and Find Full Text PDF

Aim(s): This discursive article aims to examine how systemic factors (both) reproduce the structure of settler colonialism and influence health outcomes among Indigenous peoples in the United States through settler colonial determinants of Indigenous health (SCDoIH).

Design: Discursive paper.

Methods: This discursive paper demonstrates how settler colonialism and health relate to each other within a nursing context.

View Article and Find Full Text PDF

Introduction And Aims: Dental practices pose a high risk of microbial contamination due to frequent exposure to bodily fluids like saliva and blood. Bioengineering innovations have emerged as vital tools to enhance infection control in dental settings. This review aims to assess the global applications and effectiveness of these innovations, particularly focusing on antimicrobial biomaterials, sterilization techniques, and personal protective equipment (PPE).

View Article and Find Full Text PDF

Patient- and Family-Centered Outcomes After Intensive Care Unit Admission.

Am J Crit Care

January 2025

Eliotte L. Hirshberg is an assistant professor of pediatrics, Shock Trauma Intensive Care Unit, Intermountain Medical Center, Murray, Utah; Center for Humanizing Critical Care, Intermountain Health, Murray, Utah; Pulmonary and Critical Care Medicine, Intermountain Medical Center, Salt Lake City, Utah; and Pulmonary and Critical Care Medicine, University of Utah School of Medicine, Salt Lake City.

Background: Family satisfaction with intensive care is a measure of patient experience and patient-centered care. Among the factors that might influence family satisfaction are the timing of patient admittance to the intensive care unit (ICU), the ICU environment, and individual health care providers.

Objective: To evaluate family satisfaction with the ICU and to explore associations between satisfaction and specific characteristics of the ICU stay.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!