Do monoblock cups improve survivorship, decrease wear, or reduce osteolysis in uncemented total hip arthroplasty?

Clin Orthop Relat Res

Clinical Orthopedic Research Center-midden Nederland (CORC-mN), Department of Orthopaedics, Diakonessenhuis Hospital, PO Box 80250, 3508 TG, Utrecht, The Netherlands,

Published: November 2013

Background: Monoblock acetabular components used in uncemented total hip arthroplasty (THA) have certain mechanical characteristics that potentially reduce acetabular osteolysis and polyethylene wear. However, the degree to which they achieve this goal is not well documented.

Questions/purposes: The purpose of this study was to use a systematic review of controlled trials to test the hypothesis that monoblock cups have superior (1) polyethylene wear rate; (2) frequency of cup migration; (3) frequency of acetabular osteolysis; and (4) frequency of aseptic loosening compared with modular components used in uncemented THA.

Methods: A systematic search was conducted in the Medline, Embase, and Cochrane electronic databases to assemble all controlled trials comparing monoblock with modular uncemented acetabular components in primary THA. Included studies were considered "best evidence" if the quality score was either ≥ 50% on the Cochrane Back Review Group checklist or ≥ 75% the Newcastle-Ottawa quality assessment scale. A total of seven publications met our inclusion criteria.

Results: Best evidence analysis showed no difference in polyethylene wear rate, the frequency of cup migration, and aseptic loosening between monoblock and modular acetabular components. No convincing evidence was found for the claim that lower frequencies of acetabular osteolysis are observed with the use of monoblock cups compared with modular uncemented cups.

Conclusions: The purported benefits of monoblock cups were not substantiated by this systematic review of controlled studies in that polyethylene wear rates and frequencies of cup failure and acetabular osteolysis were similar to those observed with modular implants. Other factors should therefore drive implant selection in cementless THA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3792292PMC
http://dx.doi.org/10.1007/s11999-013-3144-yDOI Listing

Publication Analysis

Top Keywords

monoblock cups
16
acetabular osteolysis
16
polyethylene wear
16
acetabular components
12
uncemented total
8
total hip
8
components uncemented
8
systematic review
8
review controlled
8
controlled trials
8

Similar Publications

Article Synopsis
  • The study focuses on evaluating the long-term performance of Vitamin E-infused highly cross-linked polyethylene (VEPE) monoblock cups in total hip arthroplasty (THA), particularly concerning migration and wear patterns over ten years.
  • The research involved 101 patients and assessed clinical outcomes using the Harris Hip Score and pain/satisfaction scales, finding significant improvements and minimal wear and migration of the cups.
  • Results showed a 100% survival rate with no need for cup-related revisions, suggesting that VEPE cups could effectively reduce issues like aseptic loosening, but longer follow-up is necessary for validation.
View Article and Find Full Text PDF

Background: The use of uncemented cups during total hip arthroplasty (THA) has gained popularity in recent years. The Robert Mathys (RM) pressfit cup, an uncemented monoblock implant is expected to preserve bone density due to its composition and external surface, while reducing backside wear with its monoblock construction. These factors should lead to a high survival rate of the implant.

View Article and Find Full Text PDF

Aims: Dislocation remains a leading cause of failure following revision total hip arthroplasty (THA). While dual-mobility (DM) bearings have been shown to mitigate this risk, options are limited when retaining or implanting an uncemented shell without modular DM options. In these circumstances, a monoblock DM cup, designed for cementing, can be cemented into an uncemented acetabular shell.

View Article and Find Full Text PDF

Lower Revision Rates and Improved Stability With a Monoblock Ceramic Acetabular Cup.

J Arthroplasty

April 2024

Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR), Adelaide, South Australia, Australia; Department of Orthopaedics, Toowoomba Hospital, Toowoomba, Queensland, Australia; University of Queensland Rural Clinical School, Toowoomba, Queensland, Australia.

Article Synopsis
  • Monoblock ceramic cups, like the DeltaMotion, are designed for total hip arthroplasty (THA) to provide better movement and stability, particularly for young and active patients.
  • A study analyzed data from over 486,000 THA procedures to compare the DeltaMotion cup with modular designs, focusing on revision rates and issues like dislocation and ceramic breakage.
  • The DeltaMotion cup showed lower overall revision rates and significantly fewer problems related to dislocation and ceramic breakage compared to modular bearings, indicating its effectiveness despite being discontinued.
View Article and Find Full Text PDF

Dislocation remains the leading cause of failure following revision total hip arthroplasty. Dual mobility (DM) constructs, including monoblock cups designed for cementation, reduce but do not eliminate this risk. Cemented DM constructs offer several unique advantages in revision total hip arthroplasty, and as such, they have gained popularity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!