A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

ASPIRE In-Home: rationale, design, and methods of a study to evaluate the safety and efficacy of automatic insulin suspension for nocturnal hypoglycemia. | LitMetric

Nocturnal hypoglycemia is a barrier to therapy intensification efforts in diabetes. The Paradigm® Veo™ system may mitigate nocturnal hypoglycemia by automatically suspending insulin when a prespecified sensor glucose threshold is reached. ASPIRE (Automation to Simulate Pancreatic Insulin REsponse) In-Home (NCT01497938) was a multicenter, randomized, parallel, adaptive study of subjects with type 1 diabetes. The control arm used sensor-augmented pump therapy. The treatment arm used sensor-augmented pump therapy with threshold suspend, which automatically suspends the insulin pump in response to a sensor glucose value at or below a prespecified threshold. To be randomized, subjects had to have demonstrated ≥2 episodes of nocturnal hypoglycemia, defined as >20 consecutive minutes of sensor glucose values ≤65 mg/dl starting between 10:00 PM and 8:00 AM in the 2-week run-in phase. The 3-month study phase evaluated safety by comparing changes in glycated hemoglobin (A1C) values and evaluated efficacy by comparing the mean area under the glucose concentration time curves for nocturnal hypoglycemia events in the two groups. Other outcomes included the rate of nocturnal hypoglycemia events and the distribution of sensor glucose values. Data from the ASPIRE In-Home study should provide evidence on the safety of the threshold suspend feature with respect to A1C and its efficacy with respect to severity and duration of nocturnal hypoglycemia when used at home over a 3-month period.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3879766PMC
http://dx.doi.org/10.1177/193229681300700424DOI Listing

Publication Analysis

Top Keywords

nocturnal hypoglycemia
28
sensor glucose
16
aspire in-home
8
arm sensor-augmented
8
sensor-augmented pump
8
pump therapy
8
threshold suspend
8
glucose values
8
hypoglycemia events
8
nocturnal
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!