Locking plates in distal humerus fractures: study of 43 patients.

Chin J Traumatol

Department of Orthopaedics, Physical Medicine, Paraplegia and Rehabilitation, Pt. BD Sharma Post Graduate Institute of Medical Sciences, Rohtak 124001, India.

Published: June 2014

Objective: The treatment of multi-fragmentary, intraarticular fractures of the distal humerus is difficult, even in young patients with bone of good quality. Small distal fragment, diminished bone mineral quality and increased trauma-associated joint destruction make stable joint reconstruction more problematic. The anatomically preshaped locking plates allow angular stable fixation for these complex fractures. We evaluated functional results of patients treated with open reduction and internal fixation with distal humerus locking plates for complex distal humerus fractures.

Methods: Forty-three consecutive patients with articular fractures of the distal humerus were treated by open reduction and internal fixation with AO distal humerus plate system and locking reconstruction plates. Forty patients were available for the final outcome analysis. According to AO/ASIF classification, there were 2 cases of type A2, 4 cases of type A3, 1 case of type B1, 1 case of type B2, 14 cases of type C1, 7 cases of type C2 and 11 cases of type C3. Open reduction with triceps splitting technique was used in all patients. The clinical and radiographic follow-up was performed and outcome measures included pain assessment, range of motion, and Mayo elbow performance score.

Results: Forty patients were available for the final outcome analysis. There were 29 males and 11 females with an average age of 38.4 years (18-73 years). Clinical and radiological consolidation of the fracture was observed in all cases at an average of 11.6 weeks (9-14 weeks). The average follow-up was 12 months (10-18 months). Using the Mayo elbow performance score the results obtained were graded as excellent or good results in 33 patients (82.5%). One patient had superficial infection, and 4 had myositis ossificans. There were no cases of primary malposition or secondary displacement, implant failure or ulnar neuropathy.

Conclusion: Anatomically preshaped distal humerus locking plate system is useful in providing stable fixation for complex distal articular fracture and facilitating early postoperative rehabilitation. The low rate of implant failure in the present study indicates that the technique is promising and warrants further investigation.

Download full-text PDF

Source

Publication Analysis

Top Keywords

distal humerus
28
cases type
20
type cases
16
locking plates
12
open reduction
12
distal
9
patients
8
fractures distal
8
anatomically preshaped
8
stable fixation
8

Similar Publications

Background: Chondroblastoma is classified as a benign bone tumor. However, postoperative local recurrence remains a concern. We analyzed the factors contributing to chondroblastoma local recurrence and the clinical challenges associated with treating these patients.

View Article and Find Full Text PDF

Sexual dimorphism of the humerus bones in a French sample: comparison of several statistical models including machine learning models.

Int J Legal Med

January 2025

Faculté de Médecine, Institut Universitaire d'Anthropologie Médico-Légale, Université Côte d'Azur, 28 Avenue de Valombrose, Nice Cedex 2, 06107, France.

Sex estimation is an important part of skeletal analysis and forensic identification. Traditionally pelvic traits are utilized for accurate sex estimation. However, the long bones, especially humerus, have been proved to be as effective for determine the sex of the individual.

View Article and Find Full Text PDF

Background: There has been an increasing interest in elbow hemiarthroplasty to circumvent the problems with total elbow arthroplasty for comminuted distal humerus fractures in the elderly. The primary aim of the study is to assess the mid-term clinical and radiological outcomes of patients undergoing TEA and hemiarthroplasty for distal humerus fractures.

Methods: Retrospective analysis of data for patients undergoing hemiarthroplasty for distal humerus fractures (OTA- C3 Comminuted total articular fractures) was done.

View Article and Find Full Text PDF

Fractures of the humerus are common on the midshaft of the bone, often causing injury to the nutrient artery. Successful fracture repair and healing requires preservation of the blood supply to the long bones which is conveyed through the nutrient foramina (NF). The topography of long bone NF varies in different populations.

View Article and Find Full Text PDF

Distal humerus physeal separation is an uncommon and often misdiagnosed injury in infants and young children, frequently resulting in delayed treatment. We report three cases of distal humerus physeal separation that presented with different clinical scenarios with different management approaches. The first case describes a nine-month-old girl who was initially treated for presumed elbow cellulitis before presentation to our centre six weeks later.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!