In this study, we prepared surface plasmon resonance (SPR) sensor using the molecular imprinting technique for myoglobin detection in human serum. For this purpose, we synthesized myoglobin imprinted poly(hydroxyethyl methacrylate-N-methacryloyl-l-tryptophan methyl ester) [poly(HEMA-MATrp)] nanofilm on the surface of SPR sensor. We also synthesized non-imprinted poly(HEMA-MATrp) nanofilm without myoglobin for the control experiments. The SPR sensor was characterized with contact angle measurements, atomic force microscopy, X-ray photoelectron spectroscopy, and ellipsometry. We investigated the effectiveness of the sensor using the SPR system. We evaluated the ability of SPR sensor to sense myoglobin with myoglobin solutions (pH7.4, phosphate buffer) in different concentration range and in the serum taken from a patient with acute myocardial infarction. We found that the Langmuir adsorption model was the most suitable for the sensor system. The detection limit was 87.6 ng/mL. In order to show the selectivity of the SPR sensor, we investigated the competitive detection of myoglobin, lysozyme, cytochrome c and bovine serum albumin. The results showed that the SPR sensor has high selectivity and sensitivity for myoglobin.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.msec.2013.04.041 | DOI Listing |
Sci Rep
January 2025
Faculty of Electrical and Computer Engineering, University of Tabriz, Tabriz, Iran.
The g-C3N4/CS biosensor was designed, fabricated, and tested using compounds such as glucose, urine, lactose, and flutamide at a molarity of 10 µM, which could demonstrate a high sensitivity of 200 μm-1 for flutamide. Powerful effective medium theory and FDTD simulation were used to predict the most favorable mode and plasmonic properties of a graphite carbon nitride and chitosan nanocomposite. The research also explores the characteristics of surface plasmon resonance exhibited by the nanocomposite as the chitosan content is adjusted.
View Article and Find Full Text PDFBiosens Bioelectron
January 2025
Innovation Center of Functional Genomics and Molecular Diagnostics Technology of Gansu Province, Lanzhou, China.
Improving the sensitivity of biosensor has always the major challenge to measure lower detection concentration of biological samples. In this paper, a novel optical fiber surface plasmon resonance (SPR) biosensor based on TiC MXene/GNRs synergistically highly enhanced sensitivity was proposed. The TiC MXene and GNRs were coated on the optical fiber sensing probe by the electrostatic layer-by-layer (ELBL) assembly method.
View Article and Find Full Text PDFBiotechnol J
January 2025
Jiangsu Co-innovation Center for Prevention and Control of Important Animal Infectious Diseases and Zoonoses, Yangzhou University, Yangzhou, Jiangsu, China.
Salmonella is a common foodborne zoonotic pathogen that poses a great threat to human health and breeding industry. The rapid detection of Salmonella is necessary for early prevention and control. In this study, a subtractive inhibition assay (SIA) based on surface plasmon resonance (SPR) for the rapid detection of Salmonella was developed.
View Article and Find Full Text PDFBiotechnol Rep (Amst)
March 2025
Department of Biology, University of York, Wentworth Way, York, YO10 5DD, UK.
Unlabelled: Ongoing research in biosensor technologies has led to advanced functional materials for healthcare diagnostics, and bacteriophages (phages), demonstrating exceptional utility due to their high specificity, accuracy, rapid, label-free, and wireless detection capabilities with minimal false-positive results. Phage-based-pathogen-detecting biosensors (PBPDBs) include surface plasmon resonance (SPR) biosensors, magnetoelastic (ME), electrochemical, and quartz crystal microbalance (QCM) biosensors. Commonly used substrates for PBPDBs are gold, silicon, glass, carbon-based materials, magnetic particles, and quantum dots.
View Article and Find Full Text PDFBiosens Bioelectron
January 2025
Beijing Institute of Technology School of Chemistry and Chemical Engineering, China. Electronic address:
Photonic crystal-based aptasensors for viral proteins detection offer the advantage of producing visible readouts. However, they usually suffer from limited sensitivity and high non-specific background noise. A significant contributing factor to these issues is the use of fixed-conformation aptamers in these sensors.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!